Installation
XHD Installation, Operation, and Maintenance Manual
23
d) Make sure that the center jackscrews do not touch the foundation surface yet.
Item Description
1.
Jackscrew
2.
Baseplate
3.
Foundation
4.
Plate
Figure 13: Jackscrews
3. Level the driver mounting pads:
NOTICE:
Remove all dirt from the mounting pads in order to ensure that the correct leveling is
achieved. Failure to do so can result in equipment damage or decreased performance.
a) Put one machinist's level lengthwise on one of the two pads.
b) Put the other machinist's level across the ends of the two pads.
c) Level the pads by adjusting the four jackscrews in the corners.
Make sure that the machinist's level readings are as close to zero as possible, both
lengthwise and across.
Use the baseplate-leveling worksheet when you take the readings.
Item Description
1.
Machinist's levels
2.
Driver's mounting pads
3.
Foundation bolts
4.
Jackscrews
5.
Grout hole
6.
Pump's mounting pads
Figure 14: Level driver mounting pads
4. Turn the center jackscrews down so that they rest on their plates on the foundation surface.
5. Level the pump mounting pads: