Commissioning, Startup, Operation, and Shutdown
XHD Installation, Operation, and Maintenance Manual
53
Install the coupling guard
WARNING:
• Running a pump without safety devices exposes operators to risk of serious personal
injury or death. Never operate a unit unless appropriate safety devices (guards, etc.) are
properly installed.
• Failure to disconnect and lock out driver power may result in serious physical injury or
death. Always disconnect and lock out power to the driver before performing any
installation or maintenance tasks.
• Electrical connections must be made by certified electricians in compliance with all
international, national, state, and local rules.
• Refer to driver/coupling/gear manufacturer's installation and operation manuals (IOM)
for specific instructions and recommendations.
WARNING:
The coupling guard used in an ATEX classified environment must be constructed from a
spark resistant material.
Required parts:
Item Description
1.
End plate, drive end
2.
End plate, pump end
3.
Guard half, 2 required
4.
3/8-16 nut, 3 required
5.
3/8 in. washer
6.
3/8-16 x 2 in. hex head bolt, 3
required
Figure 34: Required parts
1. De-energize the motor, place the motor in a locked-out position, and place a caution tag at
the starter that indicates the disconnect.
2. Put the pump-side end plate in place.
If the pump-side end plate is already in place, make any necessary coupling adjustments
and then proceed to the next step.
3. Put the pump-half of the coupling guard in place:
a) Slightly spread the bottom apart.
Summary of Contents for Goulds Pumps XHD
Page 1: ...Installation Operation and Maintenance Manual XHD ...
Page 2: ......
Page 151: ...Parts Listings and Cross Sectionals XHD Installation Operation and Maintenance Manual 149 ...
Page 153: ...Certification CE or CE ATEX XHD Installation Operation and Maintenance Manual 151 ...
Page 156: ...Certification CE or CE ATEX XHD Installation Operation and Maintenance Manual 154 ...