Maintenance
XHD Installation, Operation, and Maintenance Manual
118
5. Install the hex head capscrews (370Y) through the pedestal flange into the gland half
casing (100D) to complete assembly.
Figure 111: Capscrew installation through pedestal flange into gland half casing
Stuffing box assembly and installation
Pump model
Next step to follow
XHD Value Option
• Go to Install the seal cover instructions.
XHD
• You will need to assemble the two split stuffing
box halves before attaching the stuffing box to
the seal cover. Start with the next step, Assem-
ble the split stuffing box.
Install the seal cover
1. Lubricate and install the seal cover-to-casing volute liner gasket (351Q) onto the seal cover
(184).
2. Attach the seal cover (184) to the gland half casing (100D) using the seal cover retention
socket head cap screws (388A) and clipped washers (354A).
Figure 112: Seal cover installation
Assemble the split stuffing box - XHD
1. Position the flat gaskets (367B) between the two halves of the split stuffing box (159).
2. Assemble the two halves of the split stuffing box (with gaskets in place) using the stuffing
box shoulder bolts (328). Apply a liberal coating of silicone sealant to both faces of the split
stuffing box before the gasket is installed.
3. Attach the stuffing box (159) to the seal cover (184) using the stuffing box-to-seal cover hex
head cap screws (569L).
Summary of Contents for Goulds Pumps XHD
Page 1: ...Installation Operation and Maintenance Manual XHD ...
Page 2: ......
Page 151: ...Parts Listings and Cross Sectionals XHD Installation Operation and Maintenance Manual 149 ...
Page 153: ...Certification CE or CE ATEX XHD Installation Operation and Maintenance Manual 151 ...
Page 156: ...Certification CE or CE ATEX XHD Installation Operation and Maintenance Manual 154 ...