Maintenance
XHD Installation, Operation, and Maintenance Manual
124
9. Install the seal ring hex jam nuts (357B) on the square head adjusting bolts (356F) that now
protrude from the suction half casing (100A). Fully tighten to complete assembly.
Figure 121: Suction liner installation
10. Coat the volute liner-to-suction side liner flat gasket (351N) with lubricant and install into
the suction side liner (561).
11. Install the suction side liner holding threaded rob and nut (372N, sizes 150 and above
only).
Reassembly for Rubber-Lined
The reassembly steps for Metal-lined and Rubber-lined differ. This section, beginning with
Install the casing volute liner and ending with Install suction half casing with other suction half
components attached, pertains to Rubber-lined pumps.
For Metal-lined pumps, refer to the sub-section,
Install the casing volute liner - Rubber-lined
NOTICE: When the Dynamic Seal option is provided, be sure the power end and expeller
assembly are adjusted prior to volute liner installation so that the expeller does not interfere
with the installation of the volute liner.
1. Coat the threads of the casing volute liner retention studs (600L) that will be inserted into
the casing volute liner (600T) with anti-seize compound.