Maintenance
XHD Installation, Operation, and Maintenance Manual
88
Figure 68: Impeller removal - metal lined
4. Secure the Volute Liner hook, to the Volute Liner (561) in the proper orientation, as
illustrated below.
Figure 69: Volute liner replacement - alternate orientations
5. Lift the Hook and volute liner and crane into the Gland casing.
6. Be sure to locate the Volute Liner hook and upper and lower keys, and tighten the bolts thru
the key to the hook. This will restrict movement of the volute liner on the hook. Failure to
tighten the keys appropriately may allow the volute liner to rotate while being hoisted into
the gland casing.
Remove the shaft sleeve
1. Remove the shaft sleeve (126) from the shaft (122). Use a short pry bar to gently facilitate
removal, if necessary.
2. Remove the impeller hub o-ring (412A) and shaft sleeve o-ring (412F).