![Intel GSU31 User Manual Download Page 31](http://html1.mh-extra.com/html/intel/gsu31/gsu31_user-manual_2072234031.webp)
Intel® Integrated RAID Controller GSU31 User’s Manual
Rev 1.0
2-11
Advanced Installation Steps
Figure 2-8. Create RAID 5 Volume with 3 Disks
Highlight Submit and press Enter. The RAID 5 confirmation screen appears. If you are satisfied
with the selections you have made for your RAID 5 volume, select Yes in the confirmation screen.
The volume is created and begins to initialize.
The RAID 5 Volume Creation Complete, Successful Initialization in Progress screen is displayed
after a RAID 5 volume has been successfully created. This screen automatically updates to show
the progress of the initialization of the new RAID 5 volume. See
Note:
You do not have to wait for this operation to complete. You may use the newly created RAID
volume at any time.
Figure 2-9. RAID 5 Volume Initialization in Progress
Intel(R) Integrated RAID - RAID Configuration Utility Version 4.05
Copyright(c) Intel Corporation 1998-2000 All Rights Reserved
RAID 5 Volume Creation
Enter the name of the RAID Volume: Volume1
Enter the size of the RAID Volume: 12873
Maximum RAID Volume Size: 12873
SUBMIT
Is this the Boot Device? *YES NO
*YES
NO
Arrow Keys to Highlight, ENTER to Select.
Esc for previous menu
Intel(R) Integrated RAID - RAID Configuration Utility Version 4.05
Copyright(c) Intel Corporation 1998-2000 All Rights Reserved
RAID Volume Creation Complete
Volume Initialization In Progress
You may exit and reboot or wait for initialization to complete.
Main Menu
EXIT