background image

Intel® Integrated RAID Controller 
GSU31

User’s Manual

 

Rev 1.0

September 2000

Order Number: 273448-001

           

Summary of Contents for GSU31

Page 1: ...Intel Integrated RAID Controller GSU31 User s Manual Rev 1 0 September 2000 Order Number 273448 001...

Page 2: ...make changes to specifications and product descriptions at any time without notice Designers must not rely on the absence or characteristics of any features or instructions marked reserved or undefine...

Page 3: ...tion Utility Main Menu 2 5 2 3 3 Creating a RAID Volume in RAID Configuration Utility 2 6 2 3 4 Custom Configuration 2 13 2 3 5 Display Volume Information in RAID Configuration Utility 2 17 2 3 6 Dele...

Page 4: ...P OpenView Network Node Manager Integration 4 10 4 3 Configuring RAID Volumes Using the Intel Integrated RAID Storage Console4 12 4 3 1 Getting Started 4 12 4 3 2 Launching the Intel Integrated RAID S...

Page 5: ...AID Configuration Utility B 4 B 5 Windows NT B 4 B 6 Browser Configuration During Initial Installation B 5 B 7 Running a Browser on the Unixware Server B 7 B 8 Remote Management Microsoft Windows Term...

Page 6: ...s 2 25 2 23 Intel Integrated RAID Software Installer Main Menu 2 27 2 24 Adding Components 2 28 2 25 Intel Integrated RAID Software Installer Main Menu 2 30 2 26 Adding Components 2 31 2 27 Upgrade to...

Page 7: ...4 8 RAID Volume Actions 4 17 4 9 Create Typical Step 1 4 18 4 10 Create Typical Step 2 4 19 4 11 Select RAID Level 4 19 4 12 Add Volume Information 4 20 4 13 Modify Volume List 4 20 4 14 Modify Volume...

Page 8: ...ew Installation Files 4 11 4 3 HP OpenView Installation Operations 4 11 4 4 Intel Integrated RAID Storage Console Menu 4 14 4 5 RAID Level Selected by Storage Console Based on the Number of System Dri...

Page 9: ...e Navigator Start with CD ROM DRIVE Docs index htm Table 1 1 Documentation Chapter Appendix Title Description Chapter 1 Quick Start Instructions Abbreviated version of the installation procedure Chapt...

Page 10: ...Application Storage Console DMI Component Instrumentation SNMP Extension Agents 1 2 Introduction The GSU31 is comprised of the i960 I O processor based hardware firmware and the Intel Integrated RAID...

Page 11: ...kplate shown in Figure 1 2 1 Remove both backplate screws on the backplate edge of the adapter 2 Remove the full height backplate 3 Position the low profile backplate shown in Figure 1 2 and attach wi...

Page 12: ...large enough to contain the operating system The volume may contain more than just the host operating system if desired Note The RCU can only configure one RAID volume at a time If more than one RAID...

Page 13: ...Create an OS Installation Driver Diskette There are two methods to create a GSU31 Installation Driver Diskette Method 1 1 Insert the GSU31 CD ROM into a different system running Windows 95 98 NT or 20...

Page 14: ...crosoft Internet Explorer 4 00 or greater Not supplied 1 7 1 2 Installing Microsoft Windows 2000 or NT 4 0 on a RAID Volume 1 Boot with the Windows 2000 or NT 4 0 CD ROM 2 Press F6 as soon as the firs...

Page 15: ...tup exe For Windows NT 4 0 execute the file CD ROM root os_setup winnt setup exe Figure 1 4 Intel Integrated RAID Installer Main Menu 6 Click on the Setup button See Figure 1 4 above The RAID Software...

Page 16: ...ed 1 7 2 2 Installing Novell NetWare on a RAID Volume There are two procedures listed below one for NetWare 4 2 and another for NetWare 5 0 Please follow the instructions for the version you wish to i...

Page 17: ...files During this initialization you will see a white graphical NetWare logo screen 4 It will eventually load a Welcome screen asking you to verify the startup directory C NWSERVER Hit Alt F10 to exi...

Page 18: ...allation of your GSU31 is now complete Refer to subsequent chapters in this user s manual for additional information 1 7 3 Setup and Installation for UnixWare 7 1 1 7 3 1 Software Requirements GSU31 C...

Page 19: ...u can do so using the pkgadd 1 command 2 Install the Netscape browser The Netscape browser is provided in the SCO UnixWare CD ROM Disk 2 of 3 3 After completing the UnixWare installation insert the GS...

Page 20: ...rt Instructions Figure 1 7 Install Components 5 Press Enter to select all packages After completing the installation of the components reboot the server 6 Installation of your GSU31 is now complete Re...

Page 21: ...Installed on an Intel Integrated RAID Volume or Pass Through Disk to Windows 2000 Uninstalling GSU31 from Windows 2000 Overview of Setup and Installation for Local Administration of Windows NT 4 0 Se...

Page 22: ...etWare on a RAID Volume or Pass Through Disk Installing GSU31 on an Existing Novell NetWare Server Uninstalling GSU31 from NetWare Setup and Installation for UnixWare RAID Requirements for UnixWare In...

Page 23: ...ge appears Follow the screen instructions to create and configure a RAID volume If you do not wish to execute the RAID Configuration Utility then do nothing when this message appears The message will...

Page 24: ...f drives and their sizes in the RCU you can determine which adapter you are configuring 2 2 2 2 The Number of System Drives and RAID Level During the creation of a RAID volume by RAID Configuration Ut...

Page 25: ...Main Menu appears see Figure 2 2 RAID Configuration Utility Main Menu on page 2 6 The Status Line will vary in the opening screen in Figure 2 2 depending upon the number of disk drives found number o...

Page 26: ...hardware for the creation of a volume However you can choose how large to make the RAID volume 2 3 3 1 RAID Configuration Utility RAID Level Volume Selection The number of drives present in your syst...

Page 27: ...ty is limited to one However you may select the size of this volume Figure 2 4 RAID Volume Already Exists 2 3 3 3 Create a RAID 0 Volume A RAID 0 volume creation screen is shown in Figure 2 5 Intel R...

Page 28: ...ize Choosing the RAID Volume as a Boot Device In Figure 2 5 the RAID 0 Volume being created is selected by default to become the boot device To select the RAID 0 Volume as a boot device select Yes or...

Page 29: ...2 7 the maximum volume size available by default the maximum size always appears 8582 has been selected Another way to allocate the maximum size available to a RAID volume is to enter a size value of...

Page 30: ...e 2 8 the maximum volume size available by default the maximum size always appears 12873 has been selected Another way to allocate the maximum size available to a RAID volume is to enter a size value...

Page 31: ...ume See Figure 2 9 Note You do not have to wait for this operation to complete You may use the newly created RAID volume at any time Figure 2 9 RAID 5 Volume Initialization in Progress Intel R Integra...

Page 32: ...h Hot Spare option gives you the ability to define a global hot spare In Figure 2 10 a Global hot spare is selected an asterisk indicates the selection Select Yes to create a hot spare Choosing the RA...

Page 33: ...volume at any time 2 3 4 Custom Configuration Custom configuration allows the user to define pass through disks format disks and select boot devices Click on Custom Configuration in the Main Menu to...

Page 34: ...figuration utility and return back to the Main Menu press ESC and the utility will exit without saving changes 3 Highlight the Submit option and press Enter to view which disk will be configured as Pa...

Page 35: ...nder the Select column next to the disk Disks are identified by channel and then SCSI ID 5 Select Submit press Enter to confirm the selection 6 Select Yes at the first confirmation prompt then Yes at...

Page 36: ...highlighting it with the arrow keys and pressing Enter to mark Volumes are listed alphabetically An x will appear under the Select column next to the volume selected See Figure 2 14 Note To unselect...

Page 37: ...een Figure 2 15 Display Volume Information 2 3 6 Delete a RAID Volume in RAID Configuration Utility Use the Delete RAID Volume screen to delete a RAID volume See Figure 2 16 Each attached RAID volume...

Page 38: ...nfiguration of your system To use this feature select the Delete RAID Volume option See Figure 2 2 RAID Configuration Utility Main Menu on page 2 6 Warning If you reset the configuration in RAID Confi...

Page 39: ...pears This screen indicates that the configuration is being reset 2 3 8 Display Help Text This option displays online help Intel R Integrated RAID RAID Configuration Utility Version 4 05 Copyright c I...

Page 40: ...le is the browser based version of the Advanced RCU Use Advanced RCU to Create and configure more than one RAID volume Select specific drives to be part of a RAID volume Display Volume information Del...

Page 41: ...tion Main p1 of 1 ARROW KEYS Up and Down to move Right to follow a link Left to go back OTHER KEYS Esc to jump to Main or IOP Configuration page q to QUIT RAID Volumes View Actions Create Typical Crea...

Page 42: ...ation for Microsoft Windows 2000 2 5 2 1 In this Section RAID Requirements for Microsoft Windows 2000 Installing Microsoft Windows 2000 on a Intel Integrated RAID Volume or Pass Through Disk Installin...

Page 43: ...of 800 x 600 or higher GSU31 adapter card PCI 2 2 Compliant BIOS RAID Software Requirements GSU31 CD ROM Hard Disk Space 9 MB Minimum GSU31 Windows 2000 Installation Driver Diskette See Chapter 3 Exp...

Page 44: ...er diskette in the floppy drive Press Enter to select the Windows 2000 I2O Miniport and continue with the Windows 2000 installation Go to step b 2 If you are installing Windows 2000 using the bootable...

Page 45: ...inue with the installation 7 The top three components in the Adding Components window in Figure 2 22 are preselected Add the Remote Storage Console component if desired by clicking on the remote stora...

Page 46: ...installed the remote Storage Console on 2000 Server or Advanced Server configure Internet Information Services See Section 2 5 7 1 Configuring Internet Information Services 5 0 for Microsoft Windows...

Page 47: ...000 installation TCP IP Internet Information Services 2 After the Window 2000 installation is complete log into the system with administrative privileges and install the RAID Software Suite 3 Insert t...

Page 48: ...ive location system drive Program Files RAID Software Suite Drives Click OK to continue 9 The RAID Software Suite installation will complete Reboot when prompted 10 Log onto Windows The Found New Hard...

Page 49: ...ponent Installation on page 4 3 of the Using the Storage Console chapter for information on SNMP installation Refer to section Intel Integrated RAID Software Component Installation on page 4 3 of the...

Page 50: ...ndows 2000 system with administrative privileges 2 Insert the GSU31 CD ROM in the CD ROM drive If the Software Installation Main Menu does not appear then run the setup exe file that resides at CD ROM...

Page 51: ...gram Files RAID Software Suite Drivers click OK to continue Restart the computer when finished 11 If you installed the remote Storage Console configure Internet Information Services See Section 2 5 7...

Page 52: ...ndows 2000 Setup Wizard launches select Upgrade to Windows 2000 Recommended and complete this portion of the upgrade Windows will reboot If it doesn t auto reboot after a couple of minutes manually re...

Page 53: ...u log in to the Windows 2000 environment Close it to continue the upgrade 11 Insert the RAID Software Suite CD ROM and click Setup to run the RAID Software Suite setup program 12 When the Digital Sign...

Page 54: ...To continue setting up the adapter click Yes to get past the Digital Signature Not Found information window 15 When the Install Hardware Device Drivers window see Figure 2 30 launches for the Generic...

Page 55: ...to Windows 2000 It will detect the I2O disk drive Install and reboot You will prompted to do this for each additional volume 18 Installation of the RAID Software Suite for Windows 2000 is now complete...

Page 56: ...ect the components you wish to remove Note Do NOT clear the RAID Device Drivers component box unless you do not wish to access RAID volumes or pass thru devices connected to the RAID controller anymor...

Page 57: ...ministration of Windows NT 4 0 This chapter describes the installation procedures for GSU31 on Windows NT 4 0 These procedures include hardware installation the creation and configuration of a RAID vo...

Page 58: ...e following Windows NT 4 0 operating systems Windows NT 4 0 Server Windows NT 4 0 Server Enterprise Edition Windows NT 4 0 Workstation When installing the GSU31 kit for Microsoft Windows NT note the f...

Page 59: ...ter Note Microsoft Internet Explorer can be downloaded from the Microsoft website www microsoft com and is also included in the Microsoft Windows NT 4 0 Option Pack available as web download or CD Not...

Page 60: ...to a different system running Windows 95 98 or NT The CD ROM s auto run feature will bring up a menu that will allow creation of the GSU31 NT Installation Diskette 4 Install the following required sof...

Page 61: ...on the CD ROM b Click on the Setup button See Figure 2 35 Figure 2 35 Intel Integrated RAID Software Installer Main Menu The three components in the window in Figure 2 36 are preselected Click Next a...

Page 62: ...2 42 Intel Integrated RAID Controller GSU31 User s Manual Rev 1 0 Advanced Installation Steps Figure 2 36 Adding Components...

Page 63: ...tall GSU31 software This procedure assumes that the GSU31 hardware and Windows NT are installed and operational in your system a Insert the GSU31 CD ROM in the CD ROM drive If the Software Installatio...

Page 64: ...this procedure to install the GSU31 software 9 Install the GSU31 software run the GSU31 setup Note You must have administrative level permissions to install GSU31 software This procedure assumes that...

Page 65: ...ling the Operating System on an GSU31 RAID Volume a Pass through Disk IDE or Installing GSU31 into a System with an Existing Operating System A B A B C C D D Remote Servers Workstation Remotely Admini...

Page 66: ...e before proceeding with the setup and installation RAID Hardware Requirements Server with CD ROM Drive not attached to GSU31 One available PCI slot 32bit 33MHz recommended Monitor display resolution...

Page 67: ...U31 User s Manual Rev 1 0 2 47 Advanced Installation Steps on the GSU31 CD ROM are a later version than the OSMs currently provided by OS vendors Using OSMs other than those provided on the GSU31 CD R...

Page 68: ...Diskette Alternatively the CD ROM can be inserted into a different system running Windows 95 98 or NT The CD ROM s auto run feature will bring up a menu that will allow creation of the GSU31 NT Instal...

Page 69: ...ections are allowed to IIS on the target server then the following message will appear on the web browser after launching the GSU31 configuration utility shortcut Unable to open Driver Could not open...

Page 70: ...urn to this procedure If Microsoft Internet Explorer is used continue with this procedure 9 Install the GSU31 software run the GSU31 setup Note You must have administrative level permissions to instal...

Page 71: ...egrated RAID Software Component Installation on page 4 3 of the Using the Storage Console chapter for information on DMI and SNMP installation A progress bar appears that measures the progress of the...

Page 72: ...2 52 Intel Integrated RAID Controller GSU31 User s Manual Rev 1 0 Advanced Installation Steps Figure 2 41 Selecting Components Screen after user selects Remote Storage Console...

Page 73: ...gator 4 08 or greater 4 If your browser uses a proxy server then configure your browser using the procedure in Section B 6 Browser Configuration During Initial Installation on page B 5 and return to t...

Page 74: ...rowser follow the procedure in Section 2 5 8 Configuring IIS for use with Netscape Navigator and then return to this procedure If Microsoft Internet Explorer is used continue with this procedure 8 Ins...

Page 75: ...AID Software Component Installation for information on DMI and SNMP installation A progress bar appears that measures the progress of the GSU31 setup When this screen completes you have completed the...

Page 76: ...er then go to step 8 6 Configure Microsoft IIS Warning Due to added security in GSU31 anonymous connections must be disabled in Microsoft IIS in order to execute the GSU31 configuration utility in NT...

Page 77: ...used continue with this procedure Have all hardware and software on hand See system requirements in Section 2 5 10 2 GSU31 Hardware Installation See Section 1 4 Install the Adapter Card for detailed...

Page 78: ...ts in the window in Figure 2 41 are preselected Accept this configuration and click on Next Note The DMI and SNMP components are not selected by default Refer to section Intel Integrated RAID Software...

Page 79: ...e software It is also assumed that the Remote Storage Console option was selected during RAID Software Suite installation If not refer to Section 2 5 GSU31 Setup and Installation on page 2 22 Configur...

Page 80: ...Microsoft IIS 4 0 on Microsoft Windows NT Server 4 0 Have software on hand See system requirements in Section 2 5 4 2 If you need to use the World Wide Web service capabilities of Internet Informatio...

Page 81: ...nd selecting properties from the drop down menu Note If you have other scripts located in the Scripts directory that need anonymous access simply create a unique virtual directory that points to the S...

Page 82: ...r s Manual Rev 1 0 Advanced Installation Steps Figure 2 47 Directory Security Tab on the Scripts Properties Window g Clear the Allow Anonymous Access checkbox in the Authentication Methods window See...

Page 83: ...rated RAID Controller GSU31 User s Manual Rev 1 0 2 63 Advanced Installation Steps h Select OK and close Microsoft Internet Service Manager Return to the NT installation procedure and complete your in...

Page 84: ...upport Windows NT Challenge Response authentication If you are configuring Microsoft IIS 3 0 for use with Netscape Navigator go to step 3 If you are configuring Microsoft IIS 4 0 for use with Netscape...

Page 85: ...nformation Server folder by selecting clicking on the next to the folder c Click on next to the machine name d Expand the Default Web Site folder by selecting the next to the folder See Figure 5 9 e R...

Page 86: ...ds h Select OK and close Microsoft Internet Service Manager Note Basic Authentication requires a username and password to be entered when connecting to secured web sites including GSU31 RAID Storage C...

Page 87: ...d program will show a summary of files removed and updates completed while removing files from the system It will also recommend that the user restart the server Do not restart the server here Continu...

Page 88: ...esolution of 800 x 600 or higher recommended GSU31 Adapter Card PCI 2 2 Compliant System BIOS RAID Software Requirements GSU31 CD ROM Hard disk space minimum 4 MB MS DOS 5 x or later Required for new...

Page 89: ...X EXE and create a CONFIG SYS and AUTOEXEC BAT that loads those drivers Insert the following lines in the CONFIG SYS file files 30 buffer 20 4 Reboot the server insert the NetWare Installation CD ROM...

Page 90: ...1 Create and configure a RAID volume or pass through disk using the RAID Configuration Utility See How to Invoke Advanced RCU on page 2 20 to create and configure a RAID volume or pass through disk On...

Page 91: ...the server and install Support Pack 4 or higher Once the server installation is completed reboot the server 12 To install the Intel Integrated RAID software run the Intel Integrated RAID setup run NW...

Page 92: ...e Installation CD ROM go to the appropriate drive letter and run INSTALL BAT 4 After booting you will first be asked to Accept the License Agreement Do so and then select NetWare 4 2 then select Custo...

Page 93: ...pt to boot from it and an error will result 2 After booting you will first be asked to Accept the License Agreement Do so For a brand new volume you should then select Create a New Boot Partition 3 Ne...

Page 94: ...s then Install product not listed It will tell you that it is going to scan the A drive for installation scripts Ensure the NetWare Installation diskette is in the floppy drive hit Enter to continue 1...

Page 95: ...you that it is going to scan the A drive for installation scripts Ensure the NetWare Installation diskette is in the floppy drive hit Enter to continue 4 A screen prompt will ask which components you...

Page 96: ...Integrated RAID Controller GSU31 User s Manual Rev 1 0 Advanced Installation Steps LOAD CDBE NLM LOAD LOCNLM32 NLM LOAD WS2_32 NLM LOAD WSPIP NLM LOAD HTTP411 NLM LOAD RAIDMON NLM LOAD RAIDXA NLM LOAD...

Page 97: ...lable PCI slot 32bit 33MHz recommended Monitor display resolution of 800 x 600 or higher recommended GSU31 Adapter Card PCI 2 2 Compliant System BIOS RAID Software Requirements GSU31 CD ROM Hard disk...

Page 98: ...skette At that time insert the Unix Installation diskette when prompted To create a UnixWare Installation diskette see the Make Diskettes section in Chapter 3 Exploring the Utilities Warning Only use...

Page 99: ...ed Scripts Table 2 4 Installation Components and Preinstallation Requirements Component Name Component Package Name Packages Services Requirements Optional Packages Note Storage Console ptf7066b inetd...

Page 100: ...only be updated if the revision number of the currently installed package is older or newer 7 After completing the installation of the components launch the application using the commands in Table 2...

Page 101: ...allation of UnixWare you will be prompted to install the Network Information Services NIS package By default the installation will configure your system as an NIS client See your system administrator...

Page 102: ...unch the installer by typing the following a Type cd cdfiles os_setup unixware b Type sh install to start the install script c Select option 1 by typing 1 to install the requirements and components Fi...

Page 103: ...n See Section 1 4 Install the Adapter Card for detailed hardware installation procedures Intel Integrated RAID Software Installation 1 Reboot the system into UnixWare and install the browser if necess...

Page 104: ...at the prompt b Mount the CD ROM to the folder by typing mount F cdfs r dev cdrom cdrom1 cdfiles 2 To uninstall the GSU31 components for UnixWare a Type cd cdfiles os_setup unixware b Type sh install...

Page 105: ...31 458 6847 French language 44 131 458 6848 German language 44 131 458 6954 Italian language 44 131 458 6951 M Th F 8 00 am 5 00 pm T W 8 00 am 4 00 pm UK time Credit card calls billed at U S 25 per i...

Page 106: ...uctions may cause harmful interference to radio and television reception However there is no guarantee that interference will not occur in a particular installation If this equipment does cause interf...

Page 107: ...alified technical personnel with experience installing and configuring PCI adapter cards Read and adhere to all warnings cautions and notices in this guide and the documentation supplied with this pro...

Page 108: ......

Page 109: ...o be booted first before other devices 3 1 1 Summary of Contents ROM DOS Startup Utilities Make Diskettes Update Flash Update Flash Procedure Advanced RAID Configuration Utility RAID Recovery Recover...

Page 110: ...ixware NOS installation drivers These utilities are discussed below To generate a diskette insert the GSU31 CD ROM in the CD ROM drive in system running Windows 95 98 NT or 2000 When the GSU31 Main Me...

Page 111: ...g system Windows NT Installation Create the Microsoft RAID Device Drivers for the GSU31 solution This diskette is also known as the Microsoft Windows NT SCSI miniport diskette Installing these device...

Page 112: ...site onto a floppy disk http support intel com support motherboards server 3 To flash the firmware using the CD ROM boot the system with the GSU31 CD ROM At the Main Menu enter number 2 Update Flash a...

Page 113: ...ray and volumes are in a normal status Figure 3 5 illustrates the Flash Recovery process Figure 3 5 RAID Firmware Recovery Overview Follow the procedure below to flash the GSU31 hardware 1 Back up the...

Page 114: ...3 Flash the Firmware To Flash the firmware using the CD ROM boot the system with the GSU31 CD ROM At the Main Menu select 4 RAID Recovery and press Enter Then select 1 Production Firmware press Enter...

Page 115: ...SU31 User s Manual Rev 1 0 3 7 Exploring the Utilities f Boot the system Your firmware has been restored 3 2 1 6 User s Manual via DOS PDF A DOS based compatible PDF of the user s manual is provided o...

Page 116: ......

Page 117: ...Launching the Intel Integrated RAID Storage Console for Local Administration Launching the Intel Integrated RAID Storage Console for Remote Administration Intel Integrated RAID Storage Console RAID Vo...

Page 118: ...out a RAID Volume Reset the configuration of the Intel Integrated RAID hardware Define a global hot spare RAID Monitor Monitor and report state changes of Intel Integrated RAID The RAID Monitor consis...

Page 119: ...Components 4 2 1 RAID Monitor 4 2 1 1 Overview The RAID Monitor Service detects events from the Intel Integrated RAID subsystem and provides a local console alert The RAID Monitor consists of two sof...

Page 120: ...ck the right mouse button on the icon a configuration menu appears The configuration menu is described below Configuration Menu The following are the components of the configuration menu Properties Di...

Page 121: ...nstalled Install the GSU31 DMI Component Instrumentation CI using the procedure below Note You must have administrative level permissions to install GSU31 DMI CI software 1 Insert the GSU31 CD ROM in...

Page 122: ...window below are preselected See Figure 4 1 If the RAID device drivers RAID monitor or local or remote storage console are already installed then uncheck the appropriate boxes If the RAID device driv...

Page 123: ...es the information to the DMI browser or other management applications upon request Any changes made by the management application or DMI browser are set via the service provider The service provider...

Page 124: ...tall the DMI CI only Follow the on screen prompts to complete installation Note The DMI and SNMP components are not selected by default 4 2 2 4 Using the ISC DMI Explorer Browser to Monitor GSU31 Star...

Page 125: ...4 4 Browsing GSU31 DMI Information Refreshing Attributes Attribute values change from time to time Whenever you select a group or display a new row in a table DMI Explorer displays a snapshot of the d...

Page 126: ...w of integer values to hex or decimal format 1 Click View Options 2 Click the Attribute Format tab 3 Choose a display format 4 Click OK 4 2 3 HP OpenView Network Node Manager Integration HP OpenView N...

Page 127: ...onf c IRAID ARF c openview registration c IRAID BMP c openviewbitmaps c toolbar IRAID FRF c openview fields c IRAID ICO c openview bitmaps c IRAID LRF c openview lrf IRAID SRF c openview symbols c car...

Page 128: ...itor RAID volume status Note Use the confirmation and cancellation buttons in place of the Back Forward and Refresh buttons on the HTML browser 4 3 2 Launching the Intel Integrated RAID Storage Consol...

Page 129: ...hostname or IP Address Execute the Storage Console by entering http hostname or IP Address i2o 2 8 index htm in your HTML browser Note that Novell requires you to authenticate to the tree in which the...

Page 130: ...ew volume information or take a volume action Create Typical Create a typical RAID volume the Wizard suggests a configuration modify volume name and size only Create Custom Create a customized RAID vo...

Page 131: ...olume on page 4 20 or Delete a Volume Delete a volume from the RAID Volume List or Volume Configuration screens Select Delete in the action menu and click on the Submit button Figure 4 6 RAID Volume L...

Page 132: ...in the column next to Errors Logged to view the Error Log table Note If there is no serial number for a disk listed in the Error Log table this indicates the error is against the volume and not again...

Page 133: ...because a higher RAID level is achieved with more disks providing greater fault protection RAID level takes precedence over disk space If you would rather create a larger two disk RAID 1 than a smalle...

Page 134: ...Yes if you would like to dedicate a global hot spare If a global hot spare already exists or if there is only one available disk in your system then this step is skipped See Figure 4 9 2 In Step 2 edi...

Page 135: ...m link 1 Select the appropriate RAID Level 0 1 or 5 and submit your selection See Figure 4 11 Figure 4 11 Select RAID Level 2 Edit the volume information as appropriate Edit volume name volume size ze...

Page 136: ...4 3 5 4 Modify Volume To modify a volume 1 Click on the Modify Volume link 2 Select the volume from the list you wish to change Click on Submit See Figure 4 13 The modify volume RAID level screen appe...

Page 137: ...pears See Figure 4 15 Figure 4 15 Modify Volume Strip Size 5 Click on Yes to implement the changes to the volume 4 3 6 Physical Disks 4 3 6 1 View Actions Use the View Actions feature to view physical...

Page 138: ...determine which disk action can be completed based upon the usage and status of the drive If the disks enclosed are S M A R T capable then a field for S M A R T events will appear in the display You...

Page 139: ...ume is not detected The RAID firmware does not access a missing drive Offline Drive is unusable This state is used to prepare disks for removal from a SAF TE enclosure Pass Through Drive is not contro...

Page 140: ...tomatically be used to replace the failed member disk unless you manually mark it as normal 4 3 7 Logical Arrays 4 3 7 1 View Actions Use this feature to view the Logical Array List See Figure 4 18 Vi...

Page 141: ...drive is not offline marked as a spare or part of another array Note To expand an array you must first bring the available drive online For example in the Physical Disk List mark the drive as Online...

Page 142: ...ion Migration occurs when a volume is migrating from one RAID level to another a volume strip size changes or when a disk is added to an array See Table 5 2 7 Physical Drive Usage on page 5 11 for mor...

Page 143: ...ures Click on the View link to view information such as Enclosure ID the enclosure s Manufacturer SCSI Bus number used the number of slots available within the enclosure the number of disks inserted i...

Page 144: ...to view current volume and disk configurations See Figure 4 5 4 3 9 2 Reset Config Use this feature to reset the entire RAID configuration on the system This feature deletes all volumes all data on th...

Page 145: ...ion is confirmed The most recently selected method is the default bus scan method You may select the non default bus scan method during a a bus scan but your non default settings will only be valid fo...

Page 146: ...nd preserve any existing RAID information that has previously been stored on them If the disk s had previous information stored on them the volume s on the disk s will be visisble in Storage Console a...

Page 147: ...rage Console 4 Click on View Config under Utilities to view all volumes and disks Note For the system to see the disks when the system is powered up the user must insert the disk s into the system and...

Page 148: ...on PCI slot when the system is booted This first adapter is assigned as IOP Input Output Processor 0 To switch to the second GSU31 adapter you must manual modify the URL in the browser to indicate tha...

Page 149: ...first parameter indicates the IOP http localhost scripts iop exe 0 8 0 Note The 0 parameter directly after iop exe indicating the first IOP is being configured To switch from the first adapter to the...

Page 150: ......

Page 151: ...nd RAID 1 volumes do not require initialization RAID 5 volumes must be initialized Initialization of a RAID volume begins automatically upon its creation While the initialization proceeds as a backgro...

Page 152: ...Volume Migration allows the user to change a volume s RAID level or stripe size while the server is online and the volume is in use Since the subsystem the IOP the secondary PCI bus the volume itself...

Page 153: ...re in normal mode not degraded or failed and a idle state not rebuilding initializing transforming etc During the expansion process the RAID volumes being expanded are accessible by the system In addi...

Page 154: ...ls then the global hot spare will automatically take its place and the data previously located on the failed drive is reconstructed on the global hot spare For this feature to work properly the global...

Page 155: ...inserted No manual intervention is required For the Auto Declare Spare feature to work with an enclosure without SAF TE support a reboot or bus scan is required before the system will be able to clai...

Page 156: ...gle drive no RAID Reads are higher than a single drive Writes are about the same as a single drive Reads are up to two times faster than a single drive Writes are about the same as a single drive 5 St...

Page 157: ...n a RAID 0 volume Drives 1 15 Strip Size 4 KB 8 KB 16 KB 32 KB 64 KB 128 KB Status Normal Migrating Failed States Idle Migrating Table 5 3 RAID 1 Volume Characteristics Characteristic Minimum Maximum...

Page 158: ...etails when changing these parameters Table 5 5 RAID 10 Volume Characteristics Characteristic Minimum Maximum Capacity 1 MB RAID 10 is a combination of RAID 0 and RAID 1 n x smallest single drive capa...

Page 159: ...ical disks is referred to as a RAID volume RAID level refers to the level of data performance and protection of a RAID volume A RAID volume refers to the group of physical disks which are used to hold...

Page 160: ...is compromised or non existent Initializing A RAID volume is generating parity Initialization occurs automatically after the creation of a new RAID 5 volume RAID 5 volumes only A percent sign is disp...

Page 161: ...volume status Table 5 11 Physical Drive Status Status Description OK Drive is configured as a member Failed Accesses to drive have not completed successfully The RAID firmware does not access a faile...

Page 162: ...able OK Formats a drive or allows the drive to be reformatted after a format session has failed Begin Format In Use Failed Begin Format Available in red Failed Claim for RAID Pass through OK Gives con...

Page 163: ...until it is written to disk Data in the cache is not available to be read from the cache directly This type of caching is enabled by default when no other cache type Sequential or Full Write Back is s...

Page 164: ...When the hard drive s memory fills up it immediately writes the data to the disk and sends a successfull write reply back to the controller 5 2 9 RAID Levels Examples 5 2 9 1 Striping Disk striping is...

Page 165: ...olume will lose data if one of its member disks fails Figure 5 3 Data Map of a RAID Level 0 Volume with 4 Disks Showing the First 5 Stripes 5 2 9 3 RAID Level 1 Example A RAID 1 volume mirrors the sam...

Page 166: ...tion of RAID 0 and 1 This increases performance by spreading the load across all the disks In addition to good performance this type of array also provides high reliability but its usable capacity is...

Page 167: ...a third drive a bit from drive 1 is XOR d with a bit from drive 2 and the resultant bit is stored on drive 3 This provides a balance between performance and cost Parity calculates the data in two driv...

Page 168: ......

Page 169: ...ection provides information on key features configuration options and support interface technology for GSU31 Figure A 2 shows the key features of GSU31 Figure A 1 GSU31 Key Features LSI Logic controll...

Page 170: ...rives supported Instant availability background initialization of RAID Volumes Global Hot Spares Event Notification Figure A 2 GSU31 Adapter Card Internal 68 pin Connector External VHDCI Connector Int...

Page 171: ...16MB fixed not upgradeable Cache Downstream Write Through Full and Sequential Write Back Selectable per volume disk Write Cache configurable per disk Firmware ROM Type Flash EEPROM 2MBits x 8 flashab...

Page 172: ...onnector can be fully populated with up to 15 SCSI devices not to exceed an additive total of 15 devices as long as cable length limitations for each segment are not exceeded Termination This is a com...

Page 173: ...Rules Operation is subject to the following two conditions 1 this device may not cause harmful interference and 2 this device must accept any interference received including interference that may caus...

Page 174: ......

Page 175: ...ation Problem The boot device cannot be found Solution Enter the system BIOS utility per manufacturer directions and configure it so that the RAID volume is once again selected as the primary boot dev...

Page 176: ...the system BIOS has determined to be the first bootable drive also known as drive 0x80 does not have a MBR Master Boot Record on it In the case of the GSU31 this can be the pass through drive or volum...

Page 177: ...artition was created an MBR was also created The MBR will not be removed by deleting the partition To avoid this problem in the future it is good practice to always install NT to the drive designated...

Page 178: ...m The Intel Integrated RAID software replaces the NT miniport driver NT install driver with the NT block storage OSM The block storage OSM can bind to multiple cards and thus all GSU31 s in the system...

Page 179: ...reboot a blue screen STOP 0x0000007b message will be displayed At this point the system has not yet been converted to NTFS Boot from an MS DOS floppy disk and copy the missing drivers the ones you ha...

Page 180: ...g up the Manual Proxy Configuration window 5 Place the cursor in the Exceptions text box at the bottom of the Manual Proxy Configuration window by single clicking in the text box under Do not use prox...

Page 181: ...andard NT Server The only way to get proper access to the WTS s Storage Console is to authenticate with a local to the WTS server administrative account as opposed to a trusted account in the local ac...

Page 182: ......

Page 183: ...h Level Errors ERROR 2100 Either RAID Adapter card is not present or Flash Programming Jumper on the RAID Adapter card is not set Please turn off the system and perform following checks 1 Check if the...

Page 184: ...pecified by the user for the Update or Verify operations The possible causes of this error are an incorrectly typed filename or file is not accessible for example the floppy is not in the floppy drive...

Page 185: ...g part of the IOP flash memory this message is displayed To solve this problem change the s option at the command line to accommodate the larger file or use a smaller file to program the IOP flash mem...

Page 186: ...be programmed is in HEX format This format is not supported by this software If you CONTINUE the file will be programmed in RAID Adapter flash memory as it is without Hex to Binary conversion If you E...

Page 187: ...y Errors Error Code Range 1600 to 1749 These error messages are reported in the following format ERROR xxxx Error description The xxxx is the error code The phrase ERROR xxxx is in red text and will b...

Page 188: ......

Page 189: ...cache they desire without requiring a reboot online changes Cache Size Max The maximum size of cache that may be on the RAID controller Concurrent Multiple Strip Size The ability to support multiple s...

Page 190: ...urs Hot Swap To pull out a component from a system and plug in a new one while the power is still on and the unit is still operating Note Ensure that your system supports hot swappable drives before e...

Page 191: ...anizing the data are referred to as RAID Levels The RAID levels offered by GSU31 are 0 1 5 and 10 RAID 0 1 A combination of RAID 1 and RAID 0 Provides high performance and high availability Also known...

Page 192: ...DMI and SNMP both are provided with GSU31 SNMP Protocol SNMP stands for Simple Network Management Protocol The SNMP protocol describes the rules by which a SNMP managed device communicates with an SN...

Page 193: ...re 3 4 G global hot spare 5 4 H hardware architecture features A 3 environmental specifications A 3 SCSI interface technology A 3 specifications A 1 hardware requirements quick start 1 3 hot plug disk...

Page 194: ...27 Logical Arrays 4 24 Expand Array 4 25 migration 4 26 View Actions 4 24 Menu 4 14 Physical Disks 4 21 View Actions 4 21 RAID Volumes 4 15 Create Custom 4 19 Create Typical 4 17 Modify Volume 4 20 Vi...

Page 195: ...g in RAID Configuration Utility 2 6 volume deleting in RAID Configuration Utility 2 17 volume status 5 10 volumes 5 9 W Windows 2000 server installing on a pass through disk or IDE device 2 27 install...

Reviews: