User Manual
937
Rev. 1.1
2019-03-18
TLE984xQX
Microcontroller with LIN and Power Switches for Automotive Applications
High-Side Switch
High-Side Interrupt Status Register
HS1_CYC_ON_ACTIVE
7
rwhir
High Side 1 Cyclic ON Driver
0
B
OFF
, Cyclic ON Driver OFF
1
B
ON
, Cyclic ON Driver ON
RES
6:4
r
Reserved
Always read as 0
HS1_OL_EN
3
rw
High Side 1 Open Load Detection Enable
0
B
DISABLE
, disable open load detection
1
B
ENABLE
, enable open load detection
HS1_ON
2
rwhrs
High Side 1 On
0
B
OFF
, HS driver off
1
B
ON
, HS driver on
HS1_PWM
1
rwhir
High Side 1 PWM Enable
Note:
this flag has higher priority then HS1_ON
0
B
DISABLE
, disables control by PWM input
1
B
ENABLE
, enables control by PWM input
HS1_EN
0
rwhrs
High Side 1 Enable
0
B
DISABLE
, HS circuit power off
1
B
ENABLE
, HS circuit power on
Table 498 RESET
Register Reset Type
Reset Values
Reset Short Name
Reset Mode
Note
RESET_TYPE_3
00000000
H
RESET_TYPE_3
HS_IRQS
Offset
Reset Value
High Side Driver Interrupt Status
08
H
see
Field
Bits
Type
Description
RES
31
r
Reserved
Always read as 0
Field
Bits
Type
Description
31
31
r
RES
30
30
rwhxr
HS2_
OL_*
29
29
rwhxr
HS2_
OT_*
28
24
r
RES
23
23
rwhxr
HS2_
OC_*
22
22
rwhxre
HS2_
OL_*
21
21
rwhxre
HS2_
OT_*
20
16
r
RES
15
15
r
RES
14
14
rwhxr
HS1_
OL_*
13
13
rwhxr
HS1_
OT_*
12
8
r
RES
77
rwhxr
HS1_
OC_*
66
rwhxre
HS1_
OL_*
55
rwhxre
HS1_
OT_*
4
0
r
RES