User Manual
574
Rev. 1.1
2019-03-18
TLE984xQX
Microcontroller with LIN and Power Switches for Automotive Applications
Capture/Compare Unit 6 (CCU6)
Capture/Compare Shadow Register for Channel CC60
The registers CC60R can only be read by software, the modification of the value is done by a shadow register
transfer from register CC60SR. The corresponding shadow registers CC60SR can be read and written by
software. In capture mode, the value of the T12 counter register can also be captured by registers CC60SR if
the selected capture event is detected (depending on the selected mode).
Field
Bits
Type
Description
CCV
15:0
rh
Channel 2 Capture/Compare Value
In compare mode, the bit fields CCV contain the values that are
compared to the T12 counter value. In capture mode, the captured
value of T12 can be read from these registers.
Table 302 RESET
Register Reset Type
Reset Values
Reset Short Name
Reset Mode
Note
RESET_TYPE_3
0000
H
RESET_TYPE_3
CCU6_CC60SR
Offset
Reset Value
Capture/Compare Shadow Register for
Channel CC60
14
H
see
Field
Bits
Type
Description
CCS
15:0
rwh
Shadow Register for Channel 0 Capture/Compare Value
In compare mode, the contents of bit field CCS are transferred to
the bit field CCV for the corresponding channel during a shadow
transfer. In capture mode, the captured value of T12 can be read
from these registers.
Table 303 RESET
Register Reset Type
Reset Values
Reset Short Name
Reset Mode
Note
RESET_TYPE_3
0000
H
RESET_TYPE_3
15
0
rh
CCV
15
0
rwh
CCS