User Manual
52
Rev. 1.1
2019-03-18
TLE984xQX
Microcontroller with LIN and Power Switches for Automotive Applications
Power Management Unit (PMU)
High-side Control Register
WDT1_SEQ_FAIL
6
rh
External Watchdog (WDT1) Sequential Fail
Indicates that Watchdog is not serviced 5 times
0
B
No Fail
, System working properly
1
B
Sequential Watchdog Fail
, 5 consecutive watchdog
fails
SYS_OT
5
rh
System Overtemperature Indication Flag
Indicates System Overtemperature Condition
0
B
No Overtemperature
, System ok
1
B
Overtemperature
, System Overtemperature
SYS_CLK_WDT
4
rh
System Clock (f
sys
)Watchdog Fail
Indicates a system clock watchdog fail
0
B
No System Clock Fail
, f
sys
ok
1
B
System Clock Fail
, f
sys
failed
PMU_5V_OVL
3
rh
VDDP Overload Flag
Indicates Overload Condition at VDDP
0
B
No Overload
, VDDP ok
1
B
Overload
, VDDP Overload
PMU_1V5_OVL
2
rh
VDDC Overload Flag
Indicates Overload Condition at VDDC
0
B
No Overload
, VDDC ok
1
B
Overload
, Hall VDDC Overload
SUPP_TMOUT
1
rh
Supply Time Out
Indicates the status of the Main Supply (VDDP & VDDC) after a
certain time of Power-on reset
0
B
Main Supply ok
, VDDP or VDDC are in expected range
1
B
Main Supply fail
, VDDP or VDDC do not have stable
operating point
SUPP_SHORT
0
rh
Supply Short
Indicates the status of the Main Supply (VDDP & VDDC) after a
certain time of Power-on reset
0
B
Main Supply ok
, VDDP or VDDC are in expected range
1
B
Main Supply short
, VDDP or VDDC do not have stable
operating point
Table 12 RESET
Register Reset Type
Reset Values
Reset Short Name
Reset Mode
Note
RESET_TYPE_0
00000000
H
RESET_TYPE_0
PMU_HIGHSIDE_CTRL
Offset
Reset Value
High-side Control Register
05C
H
Field
Bits
Type
Description