User Manual
79
Rev. 1.1
2019-03-18
TLE984xQX
Microcontroller with LIN and Power Switches for Automotive Applications
Power Management Unit (PMU)
PMU_ClkWDT
4
rwh
Clock Watchdog (CLKWDT) Reset Flag
0
B
No Clock Watchdog reset executed
1
B
Clock Watchdog reset executed
PMU_LPR
3
rwh
Low Priority Resets
Note:
Low Priority Resets are PMU_SOFT &
LOCKUP
0
B
Low Priority-Reset executed
1
B
Low Priority executed
PMU_SleepEX
2
rwh
Flag which indicates a reset caused by Sleep-Exit
0
B
No reset caused by Sleep-Exit executed
1
B
Reset caused by Sleep-Exit executed
PMU_WAKE
1
rwh
Flag which indicates a reset caused by Stop-Exit
Note:
Stop-Exit with reset must be configured
explicitly in the PMU_WAKE-UP_CTRL
register
1)
0
B
No reset caused by Stop-Exit executed
1
B
Reset caused by Stop-Exit executed
SYS_FAIL
0
rwh
Flag which indicates a reset caused by a System Fail
reported in the corresponding Fail Register
0
B
No reset caused by System Fail executed
1
B
Reset caused by System Fail executed
1) Otherwise this flag is not set. The flag is always set in case of pin reset in Stop Mode (in combination with the flag
PMU_PIN).
Table 24 RESET
Register Reset Type
Reset Values
Reset Short Name
Reset Mode
Note
RESET_TYPE_1
00000000
H
RESET_TYPE_1
Field
Bits
Type
Description