2.18.2 Fixed Pulse Driving Mode
void
i8092MF_EXD_FP(
BYTE
cardNo
,
WORD
axis
,
long
data
)
Description:
This function outputs fixed pulses according to the trigger input (the falling
edge of the nEXP+ signal) from a handwheel.
Parameters:
cardNo
:
Module number
axis
:
Axis or axes (Please refer to Table 2-1.)
The axis can be either X and Y
data
:
Number of fixed pulses.
Return:
None
Example:
i8092MF_EXD_FP(1, AXIS_X, 5);
//Each time the controller detects a falling edge of an XEXP+
//signal, it will output 5 pulses to the X axis.
Example of fixed pulse driving using an external signal