ICPDAS
I-8092F Software User Manual
161
i8092_IN2_LEVEL
Format:
void
i8092_IN2_LEVEL(
unsigned char
cardNo,
WORD
axis,
WORD
nLevel)
Function:
Set the logic level of the IN2 signal.
Parameters:
cardNo
is the board number.
axis
is the motion axis code/name, as shows in Table 2-1.
nLevel
is the setting the active level of the encoder Z-phase signal (IN2).
nLevel=0, Low active; nLevel=1, Hi active.
Example:
i8092_IN2_LEVEL(1, 0xf, 0);
i8092_SET_HV
Format:
void
i8092_SET_HV(
unsigned char
cardNo,
WORD
axis,
WORD
data)
Function:
Set he home search speed (HV).
Parameters:
cardNo
is the board number.
axis
is the motion axis code/name, as shows in Table 2-1.
data
is the home search speed value. Data range:1~8000
Example:
//
Set home search speed 1000 (PPS)
i8092_SET_HV(1,
0xf,
1000);