http://www.icpdas.com
應用程式函式庫
v2.0
188
D12~8 FE4~0 Set whether the input signal filter function enables or signal
passes through. 0: through, 1: enable.
D15~13 FL2~0 Set a time constant of the filter.
FL2 ~ 0
Removable
maximum noise
width
Input signal
delay time
0
1.75µSEC
2µSEC
1
224µSEC
256µSEC
2
448µSEC
512µSEC
3
896µSEC
1.024mSEC
4
1.792mSEC
2.048mSEC
5
3.584mSEC
4.096mSEC
6
7.168mSEC
8.192mSEC
7
14.336mSEC
16.384mSEC
D15~D0 will be set to 0 while resetting.