![background image](http://html2.mh-extra.com/html/icp-das-usa/i-8092f/i-8092f_user-manual_3531635023.webp)
ICPDAS
I-8092F Software User Manual
23
Example:
i8092MF_ VRING_DISABLE(1, AXIS_X);
//disable the ring counter function for the X axis
//on module 1.
2.17 Triangle prevention of fixed pulse driving
void
i8092MF_AVTRI_ENABLE (
BYTE
cardNo
,
WORD
axis
)
Description:
This function prevents a triangle form in linear acceleration (T-curve) fixed
pulse driving even if the number of output pulses is low.
Parameters:
cardNo
:
Module number
axis
:
Axis or axes (Please refer to Table 2-1)
Return:
None
Example:
i8092MF_ AVTRI_ENABLE(1, AXIS_X);
//set the X axis of module 1 not to generate a triangle form in its speed profile.
void
i8092MF_AVTRI_DISABLE (
BYTE
cardNo
,
WORD
axis
)
Description:
This function disable the function that prevents a triangle form in linear
acceleration fixed pulse driving.
Parameters:
cardNo
:
Module number
axis
:
Axis or axes (Please refer to Table 2-1)
Return:
None
Example:
i8092MF_ AVTRI_DISABLE(1, AXIS_X);
//enable the X axis of module 1 to generate a triangle form in its