ICPDAS
I-8092F Software User Manual
160
i8092_IN0_LEVEL
Format:
void
i8092_IN0_LEVEL(
unsigned char
cardNo,
WORD
axis,
WORD
nLevel )
Function:
Set the logic level of the IN0 signal.
Parameters:
cardNo
is the board number.
axis
is the motion axis code/name, as shows in
㎜
2-1.
nLevel
is the setting the active level of home signal (IN1).
nLevel=0, Low active;
nLevel=1, Hi active.
Example:
i8092_IN0_LEVEL(1, 0xf, 0);
8092_IN1_LEVEL
Format:
void
i8092_IN1_LEVEL(
unsigned char
cardNo,
WORD
axis,
WORD
nLevel)
Function:
Set the logic level of the IN1 signal.
Parameters:
cardNo
is the board number.
axis
is the motion axis code/name, as shows in Table 2-1.
nLevel
is setting the active level of the near home signal (IN0).
nLevel=0, Low active;
nLevel=1, Hi active.
Example:
i8092_IN1_LEVEL(1, 0xf, 0);