Note:
The
SRC
that
is
displayed,
is
for
the
most
severe
error
that
is
found
during
the
search
sequence
for
the
alternate
IPL
device.
There
may
not
be
an
association
between
the
error
and
the
alternate
IPL
device
that
you
are
using.
Before
using
the
displayed
SRC
to
analyze
the
problem,
ensure
that
the
alternate
IPL
device
is
ready
and
contains
the
correct
IPL
media.
External
device
addressing:
The
external
alternate
IPL
device
must
have
a
controller
address
of
7,
6,
or
5.
For
most
devices,
the
controller
comes
with
the
address
preset
to
7,
and
you
cannot
alter
it.
For
devices
that
have
changeable
addresses,
use
the
following
information:
For
34xx,
35xx,
and
7208
models
342,
345
tape
devices
you
must
set
the
SCSI
address
to
0,
1,
or
2.
For
an
IBM
9427
8mm
Tape
Cartridge
Library,
you
must
set
the
tape
library
address
for
the
drive
that
is
used
as
the
alternate
IPL
device
to
0,
1,
or
2.
For
the
location
of
the
address
switch
on
external
devices,
see
the
information
in
the
device
installation
service
manual.
Reclaim
IOP
cache
storage
For
use
by
authorized
service
providers.
Use
this
procedure
to
reclaim
IOP
cache
storage.
1.
If
you
are
not
already
using
Dedicated
Service
Tools,
perform
an
IPL
to
DST.
See
in
the
iSeries
Service
Functions
information.
If
you
cannot
perform
a
type
A
or
B
IPL,
perform
a
type
D
IPL
from
removable
media.
Did
you
get
to
DST
with
a
Type
D
IPL?
v
No
:
Continue
with
the
next
step.
v
Yes
:
Perform
the
following:
a.
Select
Work
with
disk
units
—>
Reclaim
IOP
cache
storage
.
b.
Follow
the
on-line
instructions
to
reclaim
cache
storage.
The
system
will
automatically
perform
an
IPL
to
a
Disk
Configuration
Attention
Report
or
a
Disk
Configuration
Warning
Report
display.
Select
the
option
to
display
the
report.
Because
the
Reclaim
Cache
Storage
was
selected
after
a
D-IPL,
the
system
will
now
require
another
Reclaim
Cache
Storage
to
be
performed.
2.
Select
Work
with
disk
units
—>
Work
with
disk
unit
recovery
—>
Reclaim
IOP
Cache
Storage
.
3.
Follow
the
on-line
instructions
to
reclaim
cache
storage.
Depending
on
the
reason
for
performing
the
Reclaim
IOP
Cache
procedure,
there
may
be
a
message
requiring
the
ASP
be
cleared
before
performing
this
option,
or
a
message
stating
the
number
of
lost
sectors.
Note:
If
there
are
lost
sectors,
some
objects
may
be
damaged.
The
customer
may
have
to
load
the
damaged
objects
again.
(See
the
Backup
and
Recovery
for
more
information.)
When
the
IOP
performs
a
Reset/Reload,
if
there
is
a
storage
IOA
attached
that
is
running
the
local
load
source,
Cxxx
xxxx
codes
will
be
displayed
in
the
system
control
panel.
The
DST
console
may
then
have
a
blank
screen
with
01B
displayed
on
the
system
control
panel
for
up
to
15
minutes
before
it
is
restored.
This
ends
the
procedure.
Forms
For
use
by
authorized
service
providers.
Analyze
hardware
problems
583
Summary of Contents for 270
Page 2: ......
Page 12: ...x Hardware Remove and Replace Part Locations and Listings...
Page 279: ...Figure 3 CCIN 2881 with pluggable DIMM Analyze hardware problems 267...
Page 281: ...Figure 6 Models 830 SB2 with FC 9074 HSL and SPCN locations Analyze hardware problems 269...
Page 283: ...Figure 1b Model 840 SB3 processor tower dual line cord Analyze hardware problems 271...
Page 294: ...01 gif port and LED locations 282 Hardware Remove and Replace Part Locations and Listings...
Page 295: ...s src rzaq4519 gif locations Analyze hardware problems 283...
Page 483: ...Table 1 Cover assembly FC 5095 Expansion I O Tower Analyze hardware problems 471...
Page 614: ...602 Hardware Remove and Replace Part Locations and Listings...
Page 618: ...606 Hardware Remove and Replace Part Locations and Listings...
Page 621: ......
Page 622: ...Printed in USA SY44 5917 02...