Example
To query the log records of all users within the period from 10:00:00 on 2009-08-24 to 18:00:00
on 2009-08-24, do as follows:
huawei>
display log
{ all<K>|cli<K>|failure<K>|index<K>|memory<K>|name<K>|snmp<K> }:
all
{ <cr>|start-date<D><yyyy-mm-dd> }:
2009-08-24
{ -<K>|<cr>|start-time<T><hh:mm:ss> }:
10:00:00
{ -<K>|<cr> }:
-
{ end-date<D><yyyy-mm-dd> }:
2009-08-24
{ <cr>|end-time<T><hh:mm:ss> }:
18:00:00
Command:
display log all 2009-08-24 10:00:00 - 2009-08-24 18:00:00
---------------------------------------------------------------------------
No. UserName Domain IP-Address
65 test03 -- 10.71.42.55
Time: 2009-08-24 17:14:48
Cmd: switch language-mode
---------------------------------------------------------------------------
No. UserName Domain IP-Address
64 private -- 10.78.217.35
Time: 2009-08-24 17:08:08
Cmd:
Index1: hwFrameIndex: 0
Index2: hwSlotIndex: 9
hwBackupServerIpAddr: 10.78.217.35
hwBackupMode: 3
hwBackupFileName: /bmsuser/7341374.poz
hwBackupContent: 68
hwBackupUserNam ...
---------------------------------------------------------------------------
No. UserName Domain IP-Address
63 private -- 10.78.217.35
---- More ( Press 'Q' to break ) ----
1.5.4 Checking the System Switchover
After the active/standby switchover is performed, the services of the active control board are
switched to the standby control board. This ensures that the services run in the normal state.
Prerequisites
l
An active control board and a standby control board must be configured on the device, and
the cables must be connected correctly on the boards.
l
The patch status of the active and standby control boards must be consistent with the
hardware environment.
Precautions
l
If the data of the active and standby control boards is not completely synchronized, the
system prohibits the active/standby switchover.
NOTE
Run the
display data sync state
command to query the data synchronization status of the active and
standby control boards.
l
When the communication between the active and standby control boards fails or the standby
control board is faulty, the system prohibits the active/standby switchover.