13.3.3.3 Adding ONUs to OLT
This topic describes how to add ONUs to the OLT. ONUs can be configured only after they are
added to the OLT successfully.
Context
l
When adding ONUs, you need to bind related profiles to the ONUs, including the DBA
profile, line profile, and alarm profile.
l
An ONU can be added in two modes: offline addition and online confirmation. Select either
mode as required.
Data Planning
Table 13-5
Key data plan
Configurati
on Item
Data
DBA profile
Profile ID: 20
Profile type: Type 3
Assured bandwidth: 100 Mbit/s
Maximum bandwidth: 120 Mbit/s
Line profile
Profile ID: 10
T-CONT ID: 4
GEM port ID for management service: 11
GEM port ID for other services: 12
Networking
data
PON port: 0/3/1
ONU parameters:
l
ONU ID: 1
l
SN: 32303131B39FD641
Procedure
Step 1
Configure GPON ONU profiles.
1.
Configure a DBA profile.
huawei(config)#
dba-profile add profile-id 20 type3 assure 102400 max 122880
2.
Configure an ONU line profile.
huawei(config)#
ont-lineprofile gpon profile-id 10
huawei(config-gpon-lineprofile-10)#
tcont 4 dba-profile-id 20
//Bind T-CONT 4
to DBA profile 20
huawei(config-gpon-lineprofile-10)#
gem add 11 eth tcont 0
huawei(config-gpon-lineprofile-10)#
gem add 12 eth tcont 4
//Add GEM port 12 to
T-CONT 4
huawei(config-gpon-lineprofile-10)#
gem mapping 11 0 vlan 8
huawei(config-gpon-lineprofile-10)#
gem mapping 12 1 vlan 300
//Map GEM port 12
to CVLAN 300