------------------------------------------------------------------------------
F/S/P : 0/1/0
ONT ID : 2
Port ID : 1
MG ID : 1
Telephone NO. : 77730020
User name : huawei2
Password : user2
...//The rest of the response information is omitted.
Step 6
Apply and bind an ONU voice service profile to an SIP interface
Currently, the interface common profile, SIP agent profile, SIP service data profile, and POTS
port profile can be applied to an SIP interface, and the digitmap profile can be bound to an SIP
interface.
For profiles that can be applied to an SIP interface, if parameters in those profiles are changed,
those profiles must be reapplied to the SIP interface so that the changed parameters can take
effect. For profiles that can be bound to an SIP interface, if parameters in those profiles are
changed, those profiles do not need to be rebound to the SIP interface and the changed parameters
can take effect.
The method for applying an SIP agent profile is introduced in
. The following will
introduce the methods for applying an interface common profile, an SIP service data profile,
and a POTS port profile, and the method for binding a digitmap to an SIP interface.
1.
Apply an interface common profile.
Run the
if-sip attribute
command to apply an interface common profile to an SIP interface
or configure the interface customized parameters, or run the
ont-if-sip bat-apply from
command to bulk apply the interface common profiles to SIP interfaces. If you use these
two commands to apply the interface common profiles or configure the interface
customized parameters repeatedly, the last configurations take effect.
In this example, the default interface common profile, namely interface common profile 1
is used.
2.
Apply an SIP service data profile.
Run the
sippstnuser rightflag
command to apply an SIP service data profile to an SIP
interface or configure the interface customized parameters, or run the
ont-sippstnuser bat-
apply from
command to bulk apply the SIP service data profiles to SIP interfaces. If you
use these two commands to apply the SIP service data profiles or configure the interface
customized parameters repeatedly, the last configurations take effect.
In this example, the default SIP service data profile, namely SIP service data profile 1 is
used.
3.
Apply a POTS port profile.
Run the
pstnport electric
command to apply a POTS port profile to an SIP interface or
configure the interface customized parameters, or run the
ont-pstnport electric bat-
apply
command to bulk apply the POTS port profiles to SIP interfaces. If you use these
two commands to apply the POTS port profiles or configure the interface customized
parameters repeatedly, the last configurations take effect.
In this example, the default POTS port profile, namely POTS port profile 1 is used.
4.
Bind a digitmap profile.
Run the
sippstnuser digitmap
command to bind a digitmap profile to an SIP interface, or
run the
ont-sippstnuser bat-bind from
command to bulk apply the digitmap profiles to
SmartAX MA5600T/MA5603T/MA5608T Multi-service
Access Module
Commissioning and Configuration Guide
12 FTTO Configuration(SOHO and SME)
Issue 01 (2014-04-30)
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
1221