15.3.2.7 Adding a Remote Extended Frame to an OLT
An MA5633 that works as a remote extended frame connects to a port on a cascading board of
an optical line terminal (OLT). You can configure the remote extended frame only after adding
it to the OLT.
Prerequisites
The MA5633 management policy is set to
extend-frame
. To do so, run the
sysman centralized-
mgmt primary
command.
Context
A GPON remote extended frame is added to an OLT in the following two steps: Add the MA5633
to the OLT as a GPON optical network unit (ONU). Then add the MA5633 to the OLT as a
GPON remote extended frame.
You can use either of the methods listed in the following table to add a remote extended frame
to an OLT based on site requirements.
Table 15-24
Methods of adding a remote extended frame to an OLT
Method
Usage Scenario
Remarks
Add a remote
extended frame
in offline mode.
A carrier has planned all remote
extended frame IDs together and
the remote extended frames
must be deployed one by one.
This method facilitates remote
extended frame management.
1. You have obtained the serial
number (SN) of the remote
extended frame.
2. The remote extended frame ID has
been planned.
Add an
automatically
discovered
remote extended
frame.
A great number of remote
extended frames need to be
deployed. This method reduces
manual configurations.
1. You do not know the SN of the
remote extended frame.
2. The remote extended frame ID
does not need to be planned.
SmartAX MA5600T/MA5603T/MA5608T Multi-service
Access Module
Commissioning and Configuration Guide
15 OptiCable D-CMTS Configuration (MA5633 Working as
a Remote Extended Frame)
Issue 01 (2014-04-30)
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
1579