Index Board Source Clk-type State Priority QL
Selected
-------------------------------------------------------------------------
-----
0 H801GICK 0/19/0 ETH
Normal
0 ---
YES
-------------------------------------------------------------------------
-----
Run the
display clock mode
command to query the working mode of the clock. Ensure
that the working mode of the clock daughter board is
Tracing
.
huawei(config)#
display clock mode
Clock manage-mode:Third-mode
Clock subboard work-mode:
Tracing
l
(ONU functioning as the VDSL2 Dock device) Configure the DSLAM-side clock.
When the ONU functions as the VDSL2 Dock device, the MA5694S (ONU) is connected
upstream to the DSLAM (MA5616) through VDSL2 bonding. In this way, you need to
configure clock synchronization on the OLT, DSLAM, and ONU.
Use the line clock obtained from the upstream port as the system clock.
huawei(config)#
clock source 0/0/1
huawei(config)#
clock priority system 0
l
Configure the ONU-side clock.
When a small-cell base station is connected to an ONU through the Ethernet port, the port
transmit clock is defaulted to the system clock and cannot be modified. Therefore, you need
to configure only the system clock of the ONU.
When the ONU functions as the GPON Dock device, the MA5694S is connected upstream
to the OLT through the GPON port. In this way, you need to configure clock
synchronization on the OLT and ONU.
Use the line clock obtained from the upstream port as the system clock.
1.
Use the line clock obtained from the upstream port as the system clock.
huawei(config)#
clock source 0 0/0/0
huawei(config)#
clock priority system 0
2.
Query the configurations and status of the system clock source.
Run the
display clock source
command to query the configurations and status of the
system clock source.
huawei(config)#
display clock source
--------------------------------------------------------------------
Index Type Source State Priority QL Selected
--------------------------------------------------------------------
0 line 0/0/0 Normal 0 --- YES
1 -- -/ -/ - --- --- NO ---
2 -- -/ -/ - --- --- NO ---
3 -- -/ -/ - --- --- NO ---
4 -- -/ -/ - --- --- NO ---
5 -- -/ -/ - --- --- NO ---
6 -- -/ -/ - --- --- NO ---
7 -- -/ -/ - --- --- NO ---
8 -- -/ -/ - --- --- NO ---
9 -- -/ -/ - --- --- NO ---
--------------------------------------------------------------------
----End