12.4.1.6 Configuring the H.248-based Voice Service (Through the CLI)
The OLT manages ONUs and applies VoIP configurations to the ONU using the OMCI protocol.
This topic describes how to configure the H.248-based voice service.
Prerequisite
l
The interface data and POTS port data corresponding to the MG interface have been
configured on the MGC.
l
The OLT has been connected to the MGC. The OLT can ping the IP address of the MGC
server successfully.
l
The ONU has been added to the OLT. For details, see
l
Different voice services require different ONU software versions. Before the configuration,
ensure that the ONU software version supports H.248. For details, see relevant ONU
manuals.
Context
Table 12-23
Data plan
Item
Data
ONU line profile
Profile name: ftto_line
T-CONT ID: 4
GEM port ID: 12
ONU service profile
Profile name: ftto_ser
ONU port capability set: adaptive
Networking data
IP address of the MGC server: 200.200.200.200/24
Port ID of the MGC server: 2944
Procedure
Step 1
Configure a traffic profile.
Set the profile name to
ftto_voip
and do not limit the upstream and downstream rates. Set the
priority to
5
and packets are scheduled according to the priority carried.
Run the
display traffic table ip
command to query existing traffic profiles in the system. If the
existing traffic profiles in the system do not meet the requirements, run the
traffic table ip
command to add a traffic profile.
Step 2
Configure the mapping between a GEM port and a VLAN. Create a service VLAN and a service
flow.
SmartAX MA5600T/MA5603T/MA5608T Multi-service
Access Module
Commissioning and Configuration Guide
12 FTTO Configuration(SOHO and SME)
Issue 01 (2014-04-30)
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
1159