Table 15-26
Methods of configuring RF port parameters
Method
Usage Scenario
Remarks
Use a cable
initialization
profile to
configure RF
port parameters.
A carrier needs to deploy remote
extended frames in batches. This
method reduces data
configuration for remote
extended frames, thereby
improving service provisioning
efficiency.
Configure the RF parameter
profile for the remote extended
frames on the optical line
terminal (OLT). After the
remote extended frames are
powered on and added to the
OLT, the OLT automatically
issues the RF parameter profile
to the remote extended frames,
without requiring any software
configuration.
NOTE
After the cable initialization profile
is configured, a remote extended
frame uses the RF port parameters
configured in the profile after going
online, regardless of whether the
remote extended frame in added in
offline mode or automatically
discovered by the OLT.
l
If the RF port parameters are the
same for all the remote extended
frames to be deployed in batches,
use the cable initialization profile
to configure the parameters.
l
If the RF port parameters are
basically the same for all the
remote extended frames to be
deployed in batches, use the cable
initialization profile to configure
the parameters. Then modify
parameter settings in customized
cable configuration mode.
Customize RF
port parameters
in cable mode.
Requires differentiated plans
and configurations for RF port
parameters of remote extended
frames and the remote extended
frames must be configured one
by one.
If the RF port parameters are greatly
different for the remote extended
frames to be deployed in batches, use
this method to configure the
parameters.
Data Plan
Table 15-27
Data plan for RF port parameters
Item
Data
RF port
1/1/0
SmartAX MA5600T/MA5603T/MA5608T Multi-service
Access Module
Commissioning and Configuration Guide
15 OptiCable D-CMTS Configuration (MA5633 Working as
a Remote Extended Frame)
Issue 01 (2014-04-30)
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
1582