If not, check whether the ONT properly connects to the PC or home gateway
(HGW).
l
Verify the voice service using call emulation.
1.
Run the
ont emulational call
command to configure a call emulation test.
huawei(config)#
test
huawei(config-test)#
ont emulational call caller-port 0/1/0 1 1 telno
77730020
{ <cr>|caller-stop-time<K> }:
Command:
ont emulational call caller-port 0/1/0 1 1 telno 77730020
2.
The ONT outputs the call emulation result after the test is complete.
huawei(config-test)#
----------------------------------------------------------------
F/S/P : 0/1/0
ONT-ID : 0
ONT-POTSID : 1
Test type : caller emulational call test
Detected number : 77730020
Reported number : 77730020
Current status : test end
Test Result : success
----------------------------------------------------------------
l
Troubleshooting methods for the voice service.
1.
Check whether configurations are complete on the OLT.
–
Run the
display ont info
command to query the ONT status to check whether the
ONT is registered successfully.
–
Run the
display service-port
command to check whether the voice service flow
is configured and whether the inner VLAN ID of the service flow is consistent
with that in the data plan.
2.
Check the upstream and downstream ports by checking the MAC address learning
status.
Run the
display mac-address vlan
command to check the MAC address learning
status of the voice service VLAN.
–
If the upstream port does not learn a MAC address, check the network connections
between the upstream port and upper-layer devices and check the configurations
of upper-layer devices.
–
If the downstream port does not learn a MAC address, check whether the ONT is
activated and whether physical links are normal.
–
If both the upstream and downstream ports can learn the MAC address, record the
MAC address of the ONT and log in to the service router (SR) to check whether
an IP address is allocated to the MAC address.
3.
Check the registration status of the voice service.
–
You can run the
display ont port state
command on the OLT to query the call
connection status on the POTS port. If
Call State
is
RegisterFail
or
Connecting
for a long time, check whether the voice configuration on the MGC/
SIP server is consistent with that on the ONT.
–
If the ONT uses the H.248 protocol, you can run the
display ont mg status
command on the OLT to query the registration status of the MG interface that
connects to the ONT. If
MG Status
is
UnRegistered
or
Registering
for a long
SmartAX MA5600T/MA5603T/MA5608T Multi-service
Access Module
Commissioning and Configuration Guide
9 FTTH Configuration
Issue 01 (2014-04-30)
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
654