NOTICE
Depress the Foot Switch quickly and fully to initiate a stroke. If you depress the Foot Switch
slowly or partially, a stroke will not be initiated.
4. Momentarily depress the Foot Switch. The press should make a single stroke and stop at
top dead center.
NOTICE
If the Interrupted Stroke flashes on the display, WPC has automatically changed to Two-
hand Maintained mode. You must depress and hold the run buttons to complete the stroke
and clear the Interrupted Stroke. (see “Interrupted Stroke,” page 364). Foot Switch will not
work while the Interrupted Stroke message is on.
5. At the WPC control board, notice that the “Foot switch N/C” LED goes off and the “Foot
switch N/O” LED comes on when the Foot Switch is depressed.
6. Set Press Option switch 3 to CLOSED. Power down, then power up SmartPAC 2 with
WPC to enable the change. You are now in the foot control mode. The press should cycle
to top stop only if the Foot Switch is held down until after the Auto Carry-up angle.
7. Press and hold the Foot Switch through the Auto Carry-up angle. Release Foot Switch
after bottom dead center. The press should run and stop at top stop.
8. Press and hold the Foot Switch again. This time, release the switch before the Auto
Carry-up angle. The press should start but stop immediately when the Foot Switch is
released.
9. Press and hold both RUN/INCH buttons. The press will run and top stop.
10. Set the STROKE SELECT switch to CONT (continuous).
11. At the Operator Station, depress the PRIOR ACT switch.
12. Then depress and hold down the Foot Switch. The press should run as long as the Foot
Switch is depressed.
13. Release the Foot Switch. The press should automatically top-stop.
NOTICE
If the Foot Switch is only momentarily depressed, the press stops after a single stroke. If
allowed to stop, the PRIOR ACT switch must be depressed before another stroke is initiated.
Summary of Contents for SmartPAC 2
Page 192: ...1126800 SmartPAC 2 with WPC Integration Page 170 Chapter 2 Installing SmartPAC 2 and WPC ...
Page 294: ...1126800 SmartPAC 2 with WPC Integration Page 272 Chapter 4 SmartPAC 2 Initialization Mode ...
Page 342: ...1126800 SmartPAC 2 with WPC Integration page 320 Chapter 5 SmartPAC 2 Program Mode ...
Page 404: ...1126800 SmartPAC 2 with WPC Integration Page 382 Chapter 6 SmartPAC 2 Run Mode ...
Page 448: ...1126800 SmartPAC 2 with WPC Integration Page 426 Chapter 7 SmartPAC 2 Fault Messages ...
Page 476: ...1126800 SmartPAC 2 with WPC Integration page 454 Appendix C Updating SmartPAC 2 Firmware ...
Page 482: ...1126800 SmartPAC 2 with WPC Integration page 460 Appendix F Replacing SmartPAC 2 PC Board ...
Page 492: ...1126800 SmartPAC 2 with WPC Integration page 470 Glossary ...