number
(e.g. Vs. 2.00). You can determine the last two items, by going into "Installed
options" in the Initialization mode (see Chapter 4 for details). Here is a description of the
types of codes.
F SERIES STATUS CODES
Any codes preceded by the letter "F" are generated by WPC’s first internal processor and
are operator-resettable. This means that after you correct the malfunction, you can press
SmartPAC RESET key or the EMERGENCY STOP / RESET button on the operator station
(or remote reset switch, if installed). and resume operation. If the problem is corrected, you
will be able to run the press again. If not, you will get the same fault message again.
H SERIES STATUS CODES
Some "F" errors codes are followed by "H" status codes. Like "F" errors, these "H" codes
are operator-resettable. "H" status codes are generated by the second internal processor.
With its two independent processor systems in a single modular enclosure, WPC provides
dual diverse redundancy — the latest technology in maintaining optimum clutch/brake
control and operator safety. Both of these processor systems function independently of
each other and provide separate information to the operator. Therefore, error conditions will
be detected from either or both of the two processors resident in the system. As with "F"
series status codes, after you correct the malfunction, you can press SmartPAC's RESET
key or the EMERGENCY STOP / RESET button on the operator station (or remote reset
switch, if installed). and resume operation.
Messages Displayed Due to Press Control Problems
These messages tell you that something is wrong with the configuration of SmartPAC 2 with
WPC, or with the way your press is running. Some fault messages indicate that there is a
problem specifically related to the brake monitor and/or press control. These messages may
also indicate an internal problem with SmartPAC itself.
If you cannot correct the problem after reading the remedy, contact Wintriss Tech Support.
Whenever you need help, just remember that we have expert representatives available to help
you by phone. Be sure to provide pertinent information to expedite the resolution to your
problem.
After you have corrected the problem, press RESET. If the problem is corrected, you will be
able to run the press again. If not, you will get the same fault message.
Summary of Contents for SmartPAC 2
Page 192: ...1126800 SmartPAC 2 with WPC Integration Page 170 Chapter 2 Installing SmartPAC 2 and WPC ...
Page 294: ...1126800 SmartPAC 2 with WPC Integration Page 272 Chapter 4 SmartPAC 2 Initialization Mode ...
Page 342: ...1126800 SmartPAC 2 with WPC Integration page 320 Chapter 5 SmartPAC 2 Program Mode ...
Page 404: ...1126800 SmartPAC 2 with WPC Integration Page 382 Chapter 6 SmartPAC 2 Run Mode ...
Page 448: ...1126800 SmartPAC 2 with WPC Integration Page 426 Chapter 7 SmartPAC 2 Fault Messages ...
Page 476: ...1126800 SmartPAC 2 with WPC Integration page 454 Appendix C Updating SmartPAC 2 Firmware ...
Page 482: ...1126800 SmartPAC 2 with WPC Integration page 460 Appendix F Replacing SmartPAC 2 PC Board ...
Page 492: ...1126800 SmartPAC 2 with WPC Integration page 470 Glossary ...