1126800
SmartPAC 2 with WPC Integration
Page 148
Chapter 2
Installing SmartPAC 2 and WPC
2. At the operator station, press the PRIOR ACT switch/indicator. The PRIOR ACT
indicator should illuminate and then turn off eight seconds later.
•
If the switch/indicator does turn off in eight seconds, go to step 3.
•
If the switch/indicator does not turn off within eight seconds,
stop!
Do not go any
further! Contact Wintriss Tech Support.
3. Press the PRIOR ACT switch/indicator and, before the light goes out, press both
RUN/INCH buttons. Release the RUN/INCH buttons after bottom dead center (BDC) of
the first stroke. The press should continue running.
4. At the operator station, press the TOP STOP button. Notice that the ram stops near top
dead center (TDC).
5. Restart the press in continuous (CONT) mode.
6. Now block the light curtain and observe what the press does. It should come to an
immediate stop and the Interrupted Stroke message should flash in the display.
•
If the press comes to an immediate stop, go to step 7 to complete the test.
•
If your SmartPAC 2 with WPC does not have the muting option and the press does
not come to an immediate stop when you interrupt the light curtain, check the wiring
and rerun the test starting with step 5. If it still does not stop immediately, contact
Wintriss Tech Support.
•
If you have a SmartPAC 2 with WPC with the muting option, the ram should stop as
soon as it reaches the non-muted part of the stroke (down stroke). This is acceptable.
Go to step7 to complete the test.
•
If you have a SmartPAC 2 with WPC with the muting option, and the ram does not
stop in the non-muted part of the stroke (down stroke), check the wiring and re-run
the test starting with step 5. If the ram still does not stop in the non-muted part of the
stroke, contact Wintriss Tech Support.
NOTICE
When a stroke is interrupted, WPC automatically switches to TWO HAND MAINTAINED
SINGLE STROKE mode for the remainder of the stroke.
7. Press and hold both RUN/INCH buttons so the press completes the stroke and stops at
TDC.
Go to the next applicable test.
Summary of Contents for SmartPAC 2
Page 192: ...1126800 SmartPAC 2 with WPC Integration Page 170 Chapter 2 Installing SmartPAC 2 and WPC ...
Page 294: ...1126800 SmartPAC 2 with WPC Integration Page 272 Chapter 4 SmartPAC 2 Initialization Mode ...
Page 342: ...1126800 SmartPAC 2 with WPC Integration page 320 Chapter 5 SmartPAC 2 Program Mode ...
Page 404: ...1126800 SmartPAC 2 with WPC Integration Page 382 Chapter 6 SmartPAC 2 Run Mode ...
Page 448: ...1126800 SmartPAC 2 with WPC Integration Page 426 Chapter 7 SmartPAC 2 Fault Messages ...
Page 476: ...1126800 SmartPAC 2 with WPC Integration page 454 Appendix C Updating SmartPAC 2 Firmware ...
Page 482: ...1126800 SmartPAC 2 with WPC Integration page 460 Appendix F Replacing SmartPAC 2 PC Board ...
Page 492: ...1126800 SmartPAC 2 with WPC Integration page 470 Glossary ...