Flight Management System (FMS) for the Agusta AW139/AB139 Helicopter
A28--1146--181
REV 3 Mar 2009
Navigation
6-192
Honeywell International Inc. Do not copy without express permission of Honeywell.
D
2L
-- DB (DATA BASE) VERIFY tests the database. When the
navigation database becomes invalid, DB VERIFY must be run.
After pushing the DB VERIFY prompt, load the same database that
is in the computer from disk and record the FLASH failures (if any)
at the end of the test.
D
2R
-- Use DB (DATA BASE) HELP to look at a specific location within
the database memory. Doing so is useful only under the direction of
Honeywell engineering, since memory locations differ with each
database update.
D
3L
-- Use CLEAR CDB (CUSTOM DATA BASE) to clear the custom
database. The options are to clear pilot--defined waypoints, stored
flight plans, and NOTAMS. The FMS must be operating in
independent or single mode to have access to the page. Clearing
the custom database while operating in dual or initiated transfer is
not possible.
D
3R
-- The FMS internal data about waypoints in the flight plan is
displayed using FPL WPTS (FLIGHT PLAN WAYPOINT). These
are display--only pages. No input is permitted.
D
4L
-- The FMS internal VNAV data about waypoints is displayed
using VN (VERTICAL NAVIGATION) DATA. These are display--only
pages. No input is permitted.
D
4R
-- ZERO BITE clears the previous recordings of built--in test
equipment (BITE) results.
D
5L
-- RM index.
D
5R
-- Query information.
Summary of Contents for FMZ Series