Rev. 1.0, 09/02, page 59 of 568
4.6 Trap
Instruction
Trap instruction exception handling starts when a TRAPA instruction is executed. Trap instruction
exception handling can be executed at all times in the program execution state.
Trap instruction exception handling is conducted as follows:
1. The values in the program counter (PC), condition code register (CCR), and extended control
register (EXR) are saved to the stack.
2. The interrupt mask bit is updated and the T bit is cleared to 0.
3. A vector address corresponding to the interrupt source is generated, the start address is loaded
from the vector table to the PC, and program execution starts from that address.
The TRAPA instruction fetches a start address from a vector table entry corresponding to a vector
number from 0 to 3, as specified in the instruction code.
Table 4.4 shows the statuses of CCR and EXR after execution of trap instruction exception
handling.
Table 4.4
Statuses of CCR and EXR after Trap Instruction Exception Handling
CCR
EXR
Interrupt Control Mode
I
UI
I2 to I0
T
0 1
—
—
—
2 1
—
— 0
Legend
1:
Set to 1
0:
Cleared to 0
—:
Retains value prior to execution
Summary of Contents for H8S/2627
Page 22: ...Rev 1 0 09 02 page xx of xxxvi Index 565 ...
Page 30: ...Rev 1 0 09 02 page xxviii of xxxiv ...
Page 36: ...Rev 1 0 09 02 page xxxiv of xxxiv Table 23 9 Flash Memory Characteristics 561 ...
Page 82: ...Rev 1 0 09 02 page 46 of 568 ...
Page 88: ...Rev 1 0 09 02 page 52 of 568 ...
Page 98: ...Rev 1 0 09 02 page 62 of 568 ...
Page 156: ...Rev 1 0 09 02 page 120 of 568 ...
Page 390: ...Rev 1 0 09 02 page 354 of 568 ...
Page 480: ...Rev 1 0 09 02 page 444 of 568 ...
Page 512: ...Rev 1 0 09 02 page 476 of 568 ...
Page 528: ...Rev 1 0 09 02 page 492 of 568 ...
Page 580: ...Rev 1 0 09 02 page 544 of 568 ...