Rev. 1.0, 09/02, page 199 of 568
TCNT value
TGR
H'0000
CST bit
TGF
Time
Counter cleared by TGR
compare match
Flag cleared by software or
DTC activation
Figure 10.4 Periodic Counter Operation
Waveform Output by Compare Match: The TPU can perform 0, 1, or toggle output from the
corresponding output pin using compare match.
1. Example of setting procedure for waveform output by compare match
Figure 10.5 shows an example of the setting procedure for waveform output by compare match
Output selection
Select waveform output mode
Set output timing
Start count operation
<Waveform output>
Select initial value 0 output or 1 output, and
compare match output value 0 output, 1 output,
or toggle output, by means of TIOR. The set
initial value is output at the TIOC pin unit the
first compare match occurs.
Set the timing for compare match generation in
TGR.
Set the CST bit in TSTR to 1 to start the count
operation.
[1]
[1]
[2]
[2]
[3]
[3]
Figure 10.5 Example of Setting Procedure for Waveform Output by Compare Match
Summary of Contents for H8S/2627
Page 22: ...Rev 1 0 09 02 page xx of xxxvi Index 565 ...
Page 30: ...Rev 1 0 09 02 page xxviii of xxxiv ...
Page 36: ...Rev 1 0 09 02 page xxxiv of xxxiv Table 23 9 Flash Memory Characteristics 561 ...
Page 82: ...Rev 1 0 09 02 page 46 of 568 ...
Page 88: ...Rev 1 0 09 02 page 52 of 568 ...
Page 98: ...Rev 1 0 09 02 page 62 of 568 ...
Page 156: ...Rev 1 0 09 02 page 120 of 568 ...
Page 390: ...Rev 1 0 09 02 page 354 of 568 ...
Page 480: ...Rev 1 0 09 02 page 444 of 568 ...
Page 512: ...Rev 1 0 09 02 page 476 of 568 ...
Page 528: ...Rev 1 0 09 02 page 492 of 568 ...
Page 580: ...Rev 1 0 09 02 page 544 of 568 ...