STARTING/CHARGING (J05E)
16–7
Rotating of needle
roller front bearing
—
Sticks or does
not rotate
Replace.
Visual check
Rotating of needle
roller rear bearing
—
Sticks or does
not rotate
Replace.
Visual check
Continuity between
terminals 50 and C
1
or less
1
Replace.
Measure
Continuity between
terminal 50 and the
switch body
2
or less
2
Replace.
Measure
Inspection item
Standard
Limit
Remedy
Inspection procedure
CONTINUITY
TERMINAL
C
TERMINAL 50
OHMMETER
CONTINUITY
TERMINAL 50
OHMMETER