EXHAUST (J05E)
11–76
4.
DISCONNECTING THE HOSE.
! CAUTION
Refer to "Cautions on DEF/coolant piping attaching and detach-
ing".
Reference: EXHAUST (J05E), DEF-SCR & DPR, CAUTIONS ON
DEF/COOLANT PIPING ATTACHING AND DETACHING (Page 11-
20)
(1)
Disconnect the DEF backflow hose and DEF outlet hose from the
DEF sensor.
NOTICE
•
Prepare the reservoir and waste to collect dripping DEF when
disconnecting the hose.
•
Block with vice clip to prevent DEF from flowing out from the
hoses.
•
Mount the protection cap to the DEF sensor.
(2)
Unfasten the 2 clamps to disconnect the coolant inlet hose and
coolant outlet hose from the DEF sensor.
NOTICE
•
Prepare the reservoir and clean clothes to collect dripping
coolant when disconnecting the hose.
•
Block with vice clip to prevent coolant outflow from the hose.
•
Mount the protection cap to the DEF sensor.
5.
DISCONNECTING THE HARNESS
(1)
Disconnect the connector from the DEF sensor.
6.
REMOVING THE DEF TANK.
(1)
Remove the DEF tank from the tank bracket.
DEF TANK
DEF
SENSOR
DEF
OUTLET
HOSE
DEF
BACKFLOW
HOSE
COOLANT OUTLET
HOSE
COOLANT INLET
HOSE
SHTS021271000130
DEF SENSOR
CONNECTOR
DEF TANK
SHTS021271000131
TANK
BRACKET
DEF TANK
SHTS021271000132