EXHAUST (J05E)
11–40
5.
MOUNTING THE DIFFERENTIAL PRESSURE PIPE
(1)
Insert the differential pressure pipe into the muffler. After finger-
tightening the flare nut, tighten it to the muffler with the specified
torque.
Tightening Torque:
30-36 N·m {306-367 kgf·cm, 22.1-26.5 lbf·ft}
! CAUTION
Wipe off old anti-seizure lubricant on the differential pressure
pipes and apply new anti-seizure lubricant (equivalent to NEVER-
SEEZ Pure Nickel Special Grade manufactured by Bostic, Inc.) to
threads.
(2)
Mount the clip to the differential pressure pipe with a nut.
Tightening Torque:
31 N·m {316 kgf·cm, 22.9 lbf·ft}
6.
CONNECTING SENSORS
(1)
Mount the DPR differential pressure sensor.
(2)
Connect the DOC downstream temperature sensor.
(3)
Connect the DPR upstream temperature sensor.
(4)
Connect the DPR downstream temperature sensor.
7.
INSPECTING FOR EXHAUST GAS LEAKAGE
(1)
Start the engine and inspect for exhaust gas leakage.
DIFFERENTIAL PRESSURE PIPE
MUFFLER
SHTS021271000055