EXHAUST (J05E)
11–37
REPLACEMENT
EN01F02127100402002009
REMOVING DPR CLEANER
1.
CAUTIONS
! CAUTION
•
Perform replacement after cooling to prevent burns. (Turn the
starter key to the "LOCK" position and leave it for more than
30 minutes to cool.)
•
Handle the DPR cleaner and DEF-SCR with particular care
because they are heavy made of ceramic and can be easily
broken.
2.
DISCONNECTING SENSORS
NOTICE
Remove connectors and clips from the vehicle side. Sensors do
not need to be removed from the muffler.
(1)
Remove the DPR differential pressure sensor.
(2)
Disconnect the DOC upstream temperature sensor.
(3)
Disconnect the DPR upstream temperature sensor.
(4)
Disconnect the DPR downstream temperature sensor.
3.
REMOVING THE DIFFERENTIAL PRESSURE PIPE
(1)
Unfasten the nut to remove the clip from the differential pressure
pipe.
(2)
Loosen the flare nut to disconnect the differential pressure pipe
from the muffler.
4.
REMOVING THE FRONT EXHAUST PIPE
Reference: EXHAUST (J05E), EXHAUST PIPE, REPLACE-
MENT, REMOVING THE EXHAUST SYSTEM COMPONENT
PARTS (Page 11-9)
DIFFERENTIAL PRESSURE PIPE
MUFFLER
SHTS021271000048