INSPECTING THE LENGTH OF CONNECTING ROD BOLT
(1)
Use the vernier calipers to measure the connecting rod bolt under
head. If a measurement reading exceeds the permissible limit,
replace the head bolt.
SHANK LENGTH
SHTS021270900220
Standard value (mm {in.})
Permissible limit
(mm {in.})
67.0 {2.638}
68.0 {2.677}