EXHAUST (J05E)
11–79
REMOVING THE DEF TANK ASSEMBLY
1.
CAUTIONS
! CAUTION
After-run (DEF drawn back to the DEF tank) is performed after the
starter key is turned to “LOCK” and the muffler temperature
drops. Before starting work, wait for at least 10 minutes after turn-
ing the starter key to “LOCK.”
2.
DISCONNECTING THE HARNESS
(1)
Disconnect the connector from the DCU.
Reference: EXHAUST (J05E), DCU, REPLACEMENT, REMOV-
ING THE DCU (Page 11-90)
(2)
Disconnect the connector from the DEF sensor.
(3)
Disconnect the connector from the outside temperature sensor.
(4)
Disconnect the connector from the DEF pump.
(5)
Remove the harness clip.
DCU
OUTSIDE
TEMPERATURE
SENSOR
DEF SENSOR
SHTS021271000138
DEF PUMP
SHTS021271000139