EXHAUST (J05E)
11–88
MOUNTING THE COOLANT CUTOFF VALVE
1.
MOUNTING THE COOLANT CUTOFF VALVE
(1)
Mount the harness bracket to the coolant cutoff valve with the
bolts (2 pcs.).
Tightening Torque:
31 N·m {316 kgf·cm, 22.9 lbf·ft}
(2)
Mount the water valve bracket to the coolant cutoff valve with the
bolts (2 pcs.).
Tightening Torque:
31 N·m {316 kgf·cm, 22.9 lbf·ft}
(3)
Mount the coolant cutoff valve with the bracket with 2 nuts.
Tightening Torque:
31 N·m {316 kgf·cm, 22.9 lbf·ft}
(4)
Mount the harness clamp.
2.
CONNECTING THE HARNESS
(1)
Connect the connector to the coolant cutoff valve.
3.
CONNECTING THE HOSE
! CAUTION
Refer to "Cautions on DEF/coolant piping attaching and detach-
ing".
Reference: EXHAUST (J05E), DEF-SCR & DPR, CAUTIONS ON
DEF/COOLANT PIPING ATTACHING AND DETACHING (Page 11-
20)
(1)
Connect the 2 hoses to the coolant cutoff valve with 2 clamps.
4.
ADDING THE COOLANT
(1)
Inspect the coolant level and if insufficient, pour coolant.
Reference: COOLING (J05E), RADIATOR, REPLACEMENT,
ADDING THE COOLANT (Page 12-13)
HARNESS
BRACKET
WATER VALVE
BRACKET
COOLANT CUTOFF
VALVE
SHTS021271000154
SHTS021271000155
COOLANT CUTOFF
VALVE
SHTS021271000156