EXHAUST (J05E)
11–39
2.
TIGHTENING THE DPR CLEANER FULLY
(1)
Permanently tighten the temporarily tightened bolts and nuts.
a.
Center pipe No.1 - DPR cleaner (part A)
Tightening Torque:
20-30 N·m {204-306 kgf·cm, 14.7-22.1 lbf·ft}
b.
DPR cleaner - support bracket (part B)
Tightening Torque:
43-59 N·m {438-602 kgf·cm, 31.7-43.5 lbf·ft}
3.
MOUNTING THE FRONT EXHAUST PIPE
Reference: EXHAUST (J05E), EXHAUST PIPE, REPLACE-
MENT, MOUNTING THE EXHAUST SYSTEM COMPONENT
PARTS (Page 11-12)
4.
INSPECTING THE EXHAUST FLEXIBLE AREA MOUNTING
CONDITION
(1)
Check and confirm if the exhaust flexible area is mounted as
shown in the figure.
DPR CLEANER
A
B
B
SUPPORT
BRACKET
SUPPORT
BRACKET
CENTER
PIPE No.1
SHTS021271000053
177-191mm {6.97-7.52 in.}
BELOW
7mm{0.28 in.}
233mm{9.17 in.}
BELLOWS
SHTS021271000054