Operation Manual – System Management
H3C XE 200/2000 IP PBX
Chapter 8 Modem Management Configuration
8-8
II. Configuration procedure
# Define a Modem script
[XE] script-string dial "" AT OK ATDT8810058 CONNECT
# Execute the script on the AUX port connecting the Modem in user view
<XE> start-script dial 1
8.5 Troubleshooting the Modem
Symptom
: The Modem is in abnormal state (for example, the busy tone keeps being
played or the dial tone keeps whistling for a long time).
Solution
:
z
Execute the
shutdown
and
undo shutdown
commands on the physical interface
connected to the Modem, and then check whether the Modem restore the normal
state.
z
If the Modem is still in abnormal state, re-power the Modem.