Chapter 4: Assembling the Sidewall Sheets
4.
For 9-5 gauge laminates:
a. Extend the caulk (3) horizontally 18" (45.7 cm) between the edge of the sheet and second
horizontal seam hole at the top right of outer sheet (1O).
b. Apply a horizontal strip of caulk (5) between the overlapping vertical seam edge and second
horizontal seam hole at both the ends of the outer sheet (1O). The length of the caulk strip (5)
varies between 10" (25.4 cm) and 18" (45.7 cm).
NOTE:
Do not extend this caulking (5) into the overlapping vertical seam area.
Figure 4-6
Caulking between 5-stagger laminated sheets
1O Outer sidewall sheet
4
1/8" x 1-1/4" caulking strip (stiffener hole) (S-10716)
2
1/8" x 1/4" caulking strip (vertical) (S-4458)
5
1/8" x 1-1/4" caulking strip (horizontal – 10" to 18")
(S-10716)
3
1/8" x 1/4" caulking strip (horizontal – 18")
(S-4458)