64
3.4Troubleshooting by Error code
DX100 Service Manual
152A
Roll motor
overload error
The electric current flowing when driving the motor is irregularly
large.
• Motor cable failure
• Irregular load
• Encoder failure
• Motor failure
1. Check the connection between the Roll motor and Main Board
(CN116, CN206).
Take away the foreign objects.
Error reoccurs
• Replace the Main Board with a new
one.
• Replace the Roll motor with a new
one.
152B
Roll motor
over speed error
Detects that it is being driven at an irregularly faster speed than the
specified value just before stopping.
• Irregular load
• Encoder failure
• Motor driver failure
---
Take away the foreign objects.
Error reoccurs
• Replace the Main Board with a new
one.
• Replace the Roll motor with a new
one.
152C
Roll motor
reversing error
Detects accumulatively more than the specified number of times that
it is being driven in the opposite direction to the specified driving
direction.
• The polarity of Roll motor cable is opposite.
• Encoder failure
1. Check the connection between the Roll motor and Main Board
(CN116, CN206).
Take away the foreign objects.
Error reoccurs
• Replace the Main Board with a new
one.
• Replace the Roll motor with a new
one.
152D
Roll motor
driving time-out error
Detects that the driving period is irregularly long.
• Irregular load
• The firmware has a defect.
---
Take away the foreign objects.
Error reoccurs
• Replace the Main Board with a new
one.
• Replace the Roll motor with a new
one.
152E
Roll motor
velocity deviation error
Detects, when accelerating/decelerating the motor, that it is being
driven at an irregularly faster speed than the specified value.
• Irregular load
• Encoder failure
• Motor failure
• Motor driver failure
---
Take away the foreign objects.
Error reoccurs
• Replace the Main Board with a new
one.
• Replace the Roll motor with a new
one.
152F
Roll motor
lock error
1. Connection failure of the Roll motor.
2. Detects that it is being driven at an irregularly slower speed than
the specified value.
• Irregular load
• Encoder failure
• Motor failure
1. Check the connection between the Roll motor and Main Board
(CN116, CN206).
Take away the foreign objects.
Error reoccurs
• Replace the Main Board with a new
one.
• Replace the Roll motor with a new
one.
Table 3-5. Troubleshooting by Error Code
Code
Error Name
Cause
Check Item
Remedy
Summary of Contents for Frontier-S DX100
Page 13: ...13 DX100 Service Manual 7 3 Board Layout Diagram 299 7 4 Board Voltage List 303...
Page 14: ...C H A P T E R 1 PRODUCTDESCRIPTION...
Page 29: ...C H A P T E R 2 OPERATINGPRINCIPLES...
Page 46: ...C H A P T E R 3 TROUBLESHOOTING...
Page 76: ...C H A P T E R 4 DISASSEMBLY ASSEMBLY...
Page 208: ...C H A P T E R 5 ADJUSTMENT...
Page 279: ...C H A P T E R 6 MAINTENANCE...
Page 296: ...C H A P T E R 7 APPENDIX...
Page 298: ...298 7 2Connector Summary DX100 Service Manual 7 2 Connector Summary PW sensor...
Page 302: ...302 7 3Board Layout Diagram DX100 Service Manual Power Supply Board...