128
4.5Disassembly and Assembly Procedure
DX100 Service Manual
4.5.4.6 APG Unit
1.
Remove the Top Cover.
2.
Remove the Upper Cover.
3.
Disengage the hook of the clamp sheet, and remove the clamp sheet.
4.
Remove the Head FFC from the three tabs of the APG Unit.
5.
Remove the two screws, and then slide the FFC guide frame and remove it.
A) Silver M3x6 Bind machine screw : two pieces
Figure 4-57. Removing the Clamp sheet/FFC guide frame
6.
Release the FFC of the PF Encoder Sensor from the four tabs of the APG Unit.
7.
Disconnect the cable of the APG Motor from the relay connector.
8.
Disconnect the cable from the connector of the APG position sensor
9.
Remove the three screws that secure the APG Unit.
B) Silver M3x6 S-tite screw : three pieces
Figure 4-58. Removing the APG Unit
Clamp sheet
Hook
APG Unit
Three tabs
Head FFC
A
A
FFC guide frame
Tab
FFC of the PF
Encoder Sensor
APG Unit
B
Cable of the APG
Motor
Connector of the APG
position sensor
B
B
Relay connector
Summary of Contents for Frontier-S DX100
Page 13: ...13 DX100 Service Manual 7 3 Board Layout Diagram 299 7 4 Board Voltage List 303...
Page 14: ...C H A P T E R 1 PRODUCTDESCRIPTION...
Page 29: ...C H A P T E R 2 OPERATINGPRINCIPLES...
Page 46: ...C H A P T E R 3 TROUBLESHOOTING...
Page 76: ...C H A P T E R 4 DISASSEMBLY ASSEMBLY...
Page 208: ...C H A P T E R 5 ADJUSTMENT...
Page 279: ...C H A P T E R 6 MAINTENANCE...
Page 296: ...C H A P T E R 7 APPENDIX...
Page 298: ...298 7 2Connector Summary DX100 Service Manual 7 2 Connector Summary PW sensor...
Page 302: ...302 7 3Board Layout Diagram DX100 Service Manual Power Supply Board...