
C
HAPTER
35
| VLAN Commands
Configuring IEEE 802.1Q Tunneling
– 903 –
5.
Configure the SPVLAN ID as the native VID on the QinQ tunnel access
port (
).
6.
Configure the QinQ tunnel uplink port to dot1Q-tunnel uplink mode
(
7.
Set the Tag Protocol Identifier (TPID) value of the tunnel uplink port.
This step is required if the attached client is using a nonstandard 2-byte
ethertype to identify 802.1Q tagged frames. The standard ethertype
value is 0x8100. (See
8.
Configure the QinQ tunnel uplink port to join the SPVLAN as a tagged
member (
Limitations for QinQ
The native VLAN for the tunnel uplink ports and tunnel access ports
cannot be the same. However, the same service VLANs can be set on
both tunnel port types.
IGMP Snooping should not be enabled on a tunnel access port.
If the spanning tree protocol is enabled, be aware that a tunnel access
or tunnel uplink port may be disabled if the spanning tree structure is
automatically reconfigured to overcome a break in the tree. It is
therefore advisable to disable spanning tree on these ports.
dot1q-tunnel
system-tunnel-
control
This command sets the switch to operate in QinQ mode. Use the
no
form
to disable QinQ operating mode.
S
YNTAX
[
no
]
dot1q-tunnel system-tunnel-control
D
EFAULT
S
ETTING
Disabled
C
OMMAND
M
ODE
Global Configuration
C
OMMAND
U
SAGE
QinQ tunnel mode must be enabled on the switch for QinQ interface
settings to be functional.
E
XAMPLE
Console(config)#dot1q-tunnel system-tunnel-control
Console(config)#
Summary of Contents for DG-FS4526E
Page 4: ...ABOUT THIS GUIDE 4...
Page 34: ...CONTENTS 34...
Page 50: ...TABLES 50...
Page 52: ...SECTION I Getting Started 52...
Page 62: ...CHAPTER 1 Introduction System Defaults 62...
Page 80: ...CHAPTER 2 Initial Switch Configuration Managing System Files 80...
Page 82: ...SECTION II Web Configuration 82...
Page 100: ...CHAPTER 3 Using the Web Interface Navigating the Web Browser Interface 100...
Page 128: ...CHAPTER 4 Basic Management Tasks Resetting the System 128...
Page 166: ...CHAPTER 5 Interface Configuration VLAN Trunking 166...
Page 198: ...CHAPTER 6 VLAN Configuration Configuring VLAN Mirroring 198...
Page 516: ...CHAPTER 17 IP Services Displaying the DNS Cache 516...
Page 562: ...CHAPTER 19 Using the Command Line Interface CLI Command Groups 562...
Page 652: ...CHAPTER 22 SNMP Commands 652...
Page 660: ...CHAPTER 23 Remote Monitoring Commands 660...
Page 714: ...CHAPTER 24 Authentication Commands Management IP Filter 714...
Page 802: ...CHAPTER 27 Interface Commands 802...
Page 824: ...CHAPTER 29 Port Mirroring Commands RSPAN Mirroring Commands 824...
Page 846: ...CHAPTER 32 Address Table Commands 846...
Page 874: ...CHAPTER 33 Spanning Tree Commands 874...
Page 886: ...CHAPTER 34 ERPS Commands 886...
Page 928: ...CHAPTER 35 VLAN Commands Configuring Voice VLANs 928...
Page 942: ...CHAPTER 36 Class of Service Commands Priority Commands Layer 3 and 4 942...
Page 998: ...CHAPTER 38 Multicast Filtering Commands Multicast VLAN Registration 998...
Page 1022: ...CHAPTER 39 LLDP Commands 1022...
Page 1064: ...CHAPTER 40 CFM Commands 1064...
Page 1084: ...CHAPTER 42 Domain Name Service Commands 1084...
Page 1090: ...CHAPTER 43 DHCP Commands DHCP Client 1090...
Page 1122: ...CHAPTER 44 IP Interface Commands IPv6 Interface 1122...
Page 1124: ...SECTION IV Appendices 1124...
Page 1130: ...APPENDIX A Software Specifications Management Information Bases 1130...
Page 1152: ...COMMAND LIST 1152...
Page 1161: ......
Page 1162: ...DG FS4526E 042012 HW R01...