Central management
Configure Digi Remote Manager
AnywhereUSB® Plus User Guide
454
3. Click
Central management
.
The Central management configuration window is displayed.
Digi Remote Manager support is enabled by default. To disable, click
Enable central
management
.
4. (Optional) For
Service
, select either
Digi Remote Manager
or
Digi aView
. The default is
Digi
Remote Manager
.
5. (Optional) For
Management server
, type the URL for the central management server. The
default is the Digi Remote Manager server,
6. (Optional) For
Management port
, type the destination port for the remote cloud services
connection. The default is
3199
.
7. (Optional) For
Retry interval
, type the amount of time that the AnywhereUSB Plus device
should wait before reattempting to connect to remote cloud services after being disconnected.
The default is 30 seconds.
Allowed values are any number of hours, minutes, or seconds, and take the format
number
{
h|m|s
}.
For example, to set
Retry interval
to ten minutes, enter
10m
or
600s
.
8. (Optional) For
Keep-alive interval
, type the amount of time that the AnywhereUSB Plus device
should wait between sending keep-alive messages to remote cloud services when using a non-
cellular interface. The default is 60 seconds.
Allowed values are any number of hours, minutes, or seconds, and take the format
number
{
h|m|s
}.
For example, to set
Keep-alive interval
to ten minutes, enter
10m
or
600s
.
9. (Optional) For
Cellular keep-alive interval
, type the amount of time that the AnywhereUSB
Plus device should wait between sending keep-alive messages to remote cloud services when
using a cellular interface. The default is 290 seconds.
Allowed values are any number of hours, minutes, or seconds, and take the format
number
{
h|m|s
}.
For example, to set
Cellular keep-alive interval
to ten minutes, enter
10m
or
600s
.
10. (Optional) For
Allowed keep-alive misses
, type the number of allowed keep-alive misses. The
default is
3
.
11.
Enable watchdog
is used to monitor the connection to remote cloud services. If the
connection is down, you can configure the device to restart the connection, or to reboot. The
watchdog is enabled by default.
Summary of Contents for AnywhereUSB Plus
Page 1: ...AnywhereUSB Plus User Guide Firmware version 21 8 ...
Page 212: ...Interfaces Bridging AnywhereUSB Plus User Guide 212 ...
Page 308: ...Services Configure the ping responder service AnywhereUSB Plus User Guide 308 iperf Done ...
Page 509: ...File system Upload and download files AnywhereUSB Plus User Guide 509 sftp exit ...
Page 604: ...Virtual Private Networks VPN IPsec AnywhereUSB Plus User Guide 604 ...