SERIES 4000 12/16V SERVICE MANUAL
6. Replace valve guide if necessary.
7. Check inner diameter of valve guide with bore gage. See Figure 369.
1. Plug Gage, Design A
Figure 369
Checking Valve Guide Inner Diameter
[a]
If diameter is outside limits, replace valve guide.
[b]
If diameter is not outside limits, continue to next step.
NOTE:
Instead of bore gage, a plug gage (version A) may also be used. Nominal diameter of
plug gage: 11.009 ± 0.009. Length of go-end: 103 mm (4.0551 in.). Go-end plug gage
must move easily through the whole valve guide. No-go-side plug gage must not rub.
Installing Cap Plug
Perform the following steps to install cap plug:
All information subject to change without notice.
Copyright © DETROIT DIESEL CORPORATION
C -493
Summary of Contents for 4000 Series