1. See Figure 294for the arrangement of the testing device.
NOTE:
To check axial parallelism and twist of connecting rod bores, install connecting rod cap
and tighten connecting rod bolts as per tightening specifications.
1. Dial Gage for Axial Parallelism
6. V-Block
2. Test Brass Drift, Small Connecting Rod Eye
7. Base Plate
3. Dial Gage for Connecting Rod Twist
8. Resilient Stop
4. Connecting Rod
9. Adjustable Dial Gage Holder
5. Test Brass Drift, Large Connecting Rod Eye
Figure 294
Checking Axial Parallelism and Twist of Connecting Rod Bore
2. Clean large and small connecting rod bore.