SERIES 4000 12/16V SERVICE MANUAL
C 202.05.11 –
INSTALLATION OF HIGH-TEMPERATURE WATER PUMP
Perform the following steps to install the high – temperature water pump:
1. Coat O-ring (4) with petroleum jelly and insert in groove on bearing housing of
high–temperature water pump. See Figure 890.
1. Hex Bolt
4. O-ring
2. Washer
5. Hex Nut
3. Pump Housing
Figure 890
Installing High – Temperature Water into Bore in Gear Case
2. Position water pump correctly and install into bore in gear case, ensuring that gear engages.
3. Check gear lash.