5. Install charge air manifolds (6) with triangular flange side on charge air manifold “Y”
pipes (2). See Figure 712.
1. Retaining Plate
4. Pipe Clamp
2. Charge Air Manifold "Y" Pipe
5. Adaptor
3. Hex Bolt
6. Charge Air Manifold
Figure 712
Installing Charge Air Manifolds with Triangular Flange Side on
Forked Charge Air Manifold “Y” Pipe
6. Install pipe clamps (4) on round flange ends.
7. Coat O-rings with petroleum jelly and install on adaptors (5).
8. Install adaptors in turbocharger.
9. Position adaptors on charge air manifold ends and secure with pipe clamps (4).
10. Install retaining plate (1) and bracket with hex bolt (3) on charge air manifold.