SERIES 4000 12/16V SERVICE MANUAL
C 208.05.08 M – CLEANING, INSPECTION AND REPAIR
Exterior of the Surge Tank
Perform the following steps to clean, inspect and repair the exterior of the surge tank:
To avoid an eye injury when using compressed air, wear
adequate eye protection (safety glasses or faceplate) and
do not exceed 276 kPa (40 lb/in.
2
) air pressure.
1. Using a cloth soaked with diesel fuel, wipe the exterior of the surge tank clean and dry
with compressed air.
2. Visually inspect the surge tank for damage.
[a]
If damage is found, repair as necessary.
[b]
If damage is beyond repair, replace the surge tank.
[c]
If no damage is found, reuse the surge tank.
Interior of the Surge Tank
Perform the following steps to clean, inspect and repair the interior of the surge tank:
1. Rinse the interior of the surge tank with a solution of water and soap.
2. Rinse the interior of the surge tank with clean water.
3. Perform a pressure test of the surge tank to check for leaks.
[a]
If leaks are found, repair the surge tank as necessary.
[b]
If no leaks are found, reuse the surge tank.
All information subject to change without notice.